3 Getting Started
33
3.3.4
Remote LEDs and Recovery Switch
The PTP 300/500/600 Series Bridge PIDU Plus provides a facility to connect remote LEDs
and Recovery switch allowing the PIDU Plus to be mounted inside an enclosure. At the left
hand end of the PIDU Plus under the ODU connection cover can be found a PCB header and
three jumpers. Jumpers J906 and J907 should be removed and connection to the remote
LEDs and Recovery switch made to J908 as shown in Figure 9.
Figure 9 - Remote LED and Recovery Switch Wiring
3.3.5
Cables and connectors
The cable used to connect the PTP 300/500/600 Series Bridge PIDU Plus to the ODU can be
any standard CAT5e type provided that it is suitable for outdoor deployment. Motorola
recommends that cables to the specification below be used:
Cable:
Superior Essex BBDGE CAT 5e
Connector Type:
Tyco, 5-569278
Gland:
Motorola WB1811
CAUTION:
Failure to use the recommended (or equivalent) standard of cable may invalidate
the system’s safety certification.
The cable used to connect the PTP 500 Series Bridge PIDU Plus to the users Network
Equipment can be any standard CAT5e Cable.