User Guide: PTP 600 Series
Cables and connectors
phn-0896_009v003
Feb 2010
UNDER DEVELOPMENT
1-17
Indoor connections
The cable used for indoor connections, for example from the PIDU Plus to the network,
can be any standard screened or unscreened CAT5e cable. The recommended
connectors and glands to be used for indoor cables are specified in
.
Table 1-5
Recommended indoor CAT5e connectors
Item
Manufacturer
Part number
Connector Tyco
(AMP)
336330-1
Crimp tool
Tyco (AMP)
790163-1 (includes die set)
The PIDU Plus provides screen continuity between the ODU and network equipment
connections.
NOTE
The ODU network connection implements automatic MDI/MDI-X sensing and
pair swapping, allowing connection to networking equipment that requires
cross-over cables (MDI-X networks) or straight-through cables (MDI
Networks).