Specifications
http://www.mcg.mot.com/literature
1-9
1
Specifications
The MVME761 transition module specifications are shown in
.
Cooling requirements
The MVME761-0x1 is tested to operate under forced air cooling with an
incoming air temperature range of 0 degrees C to 55 degrees C. Adequate
cooling can be achieved with air flowing over the module at 5 cubic feet
per minute. The exact amount of airflow required for cooling depends on
the ambient air temperature and the type, number, and location of modules
and other heat sources.
FCC compliance
The MVME761-0x1 was tested in an FCC-compliant chassis, and meets
the requirements for Class A equipment. For minimum RF emissions, it is
essential that you implement the following conditions:
❏
Install shielded cables on all external I/O ports
❏
Connect conductive chassis rails to earth ground to provide a path
for connecting shields to earth ground
❏
Tighten all front panel screws
Table 1-6. MVME761-0
x1 specifications
Characteristics
Specifications
Power Requirements
+12Vdc, 100mA typical, 200mA maximum
-12Vdc, 100mA (for some of the SIMs)
Operating temperature
0
o
to 55
o
C at chassis point of entry of forced air
(approximately 5 CFM)
Storage temperature
-40
o
to +85
o
C
Relative Humidity
5% to 90% (non-condensing)
Board Size
(excluding front panel)
Height: 9.187 inches(233.35 mm)
Height: 3.200 inches(80.00 mm)
Thickness: 0.063 inches (1.60 mm)