of 48
31
L7082 / L7089
6.6
Testing on HP8922
NB* To test the PCB on its own without a housing or SIM card the unit must first be put into test mode and then
into Tx or Rx mode using the applicable manual test commands. Ensure that a battery is present during this, as the
battery acts as a SIM card presence detect for the unit. The PCB can then be taken out of the housing for any
analysis.
6.7 Testing IrDA Port
To test the IrDA port the following set up should be followed, the distance between handset and IrDA port should
be less than 30cm and although accurate alignment is not neccesary the two should be lined up as well as possible.
Note. Software is required for both the L7082 / L7089 IrDA link and also the host IrDA port.
A CD Rom will be shipped with the unit to enable data transfer, the drivers for the host IrDA device should be
supplied with the device. For testing all we are looking for is the discovery frame between PC and handset.
•
Please note this set up can only be used for Data Transfer not
Flashing or Flexing.
Also,Windows NT does not have the drivers to support IrDA
HP8922
GSM Test
Set
83220E
Down
Converter
RF Cable
L7082 / L7089
Under Test
Power Supply
PSU Cable
PC
Stand Alone
IrDA port
L7082 / L7089
!
!
Summary of Contents for L7082
Page 4: ...of 48 iv L7082 L7089 SECTION 1 GENERAL ...
Page 8: ...of 48 1 L7082 L7089 SECTION 2 L7082 L7089 DESCRIPTION ...
Page 13: ...of 48 6 L7082 L7089 SECTION 3 FEATURE LIST ...
Page 20: ...of 48 13 L7082 L7089 SECTION 4 DISASSEMBLY PARTS ...
Page 28: ...of 48 21 L7082 L7089 SECTION 5 SIM CARDS AND SECURITY ...
Page 33: ...of 48 26 L7082 L7089 SECTION 6 REPAIR AND TEST PROCEDURES ...
Page 40: ...of 48 33 L7082 L7089 SECTION 7 ACCESSORIES ...
Page 43: ...of 48 36 L7082 L7089 SECTION 8 GLOSSARY OF TERMS ...
Page 49: ...L7082 L7089 RF SCHEMATICS ...
Page 50: ...L7082 L7089 AL SCHEMATICS ...
Page 53: ...L7082 L7089 BOARD LAYOUT PAGE 1 2 ...