Chapter 8 Software Commands
Gen 3 Site Controller System Manual
MMI Commands
8-2
68P80801E30-A 5/1/2002
MMI Commands
MMI commands are input from a service computer to the system RS-232
serial port (19200 bps, 8 data bits, 1 stop bit, no parity). The RS-232 port is
accessed from the site controller Service Access connector.
The service technician enters the MMI commands to communicate with the
site controller at the system level. The system response is returned to the
service computer via RS-232.
The appropriate test procedures use these commands to test and configure
the system. The test procedure for the site controller appears in the System
Testing chapter of this manual and the test procedure for the BR appears in
the
EBTS System Manual (on CD: 98P80800A17) Base Radio
chapter
.
Access Level
Site controller commands are available through the use of the password
factory
. This password allows the service technician access to a subset of
the MMI command set. This subset is used for field service and does not
allow permanent configuration of the site controller.
Note:
The
factory
password is a default password that is programmed
during manufacturing. The password may be changed by the
Operations and Maintenance Center (OMC).
Conventions
The syntax for each command is presented as follows:
■
bold
text shows the actual text to be typed at the iSC> prompt to invoke a
command or action
■
italic
text shows the syntax used for a command
■
text enclosed in brackets [ ] indicates an optional value that may be
entered.
■
Where items are separated by vertical bars | , the items are the applicable
choices that may be entered
■
italic
text enclosed in braces < > indicates a corresponding selection or
parameter that
must
be entered for the command to execute