Grounding Connection
Figure 4-14
Station Ground Point on the Expansion Cabinet Junction Panel
Procedure 4-4
How to Provide Grounding Connection to the Equipment Cabinet
1
Strip the end of the wire to be connected to the station ground point in the junction panel.
2
Using an appropriate tool, attach a crimp lug onto the cabinet ground wire. Ensure that the lug is
securely fastened to wire.
3
Use a star type and a regular lock washer, which should be placed between the screw and the
lug (as shown in
). The regular lock washer must be placed above the lug. The lug
must have direct contact to the surface of the cabinet (no washer of any kind between the lug
and the surface to which it contacts).
Figure 4-15
Cabinet Grounding
6802800U74-N September 2009
4-19