MTS 4 CAN Bus Cabling
Chapter 5: Interconnection and Internal Cabling
MTS 4 CAN Bus Cabling
The Site Controller contains the internal termination in one end of the CAN Bus, and the last
Duplexer in the CAN Bus has a terminator in one connector.
and
identify
and
and
show the CAN Bus cabling in MTS 4.
CAN Bus cabling depends on
fi
lter con
fi
guration.
Table 5-28
CAN Bus Cabling for MTS 4 with TX/RX or TX on 1 ant.
Index
Cable Part
Number
From Unit / Connection
Name
To Unit / Connection Name
Notes
MTS 4 (TX/RX or TX on 1 ant. with ATCCs)
1
3066575B01 Site Controller 1/ CAN
Power Supply Unit 1/ CAN1
Red cable
2
3066544B06 Power Supply Unit 1/ CAN2
Duplexer or Post Filter/ CAN1
Red cable
3
3066544B09 Duplexer or Post Filter/ CAN2 ATCC 1/ CAN1
Red cable
4
3066544B09 ATCC 1/ CAN2
ATCC 2/ CAN1
Red cable
5
3066544B06 ATCC 2/ CAN2
Power Supply Unit 2/ CAN1
Red cable
6
3066575B01 Power Supply Unit 2/ CAN2
Site Controller 2/ CAN
With
redundant Site
Controller/
red cable
7
0966513A01 Power Supply Unit 2/ CAN2
CAN Bus termination
Without
redundant Site
Controller
When MTCCs or HCs are used instead of ATCCs, the CAN Bus is connected directly from
Duplexer or Post Filter/ CAN2 connector to Power Supply Unit 2/ CAN1 connector.
5-54
6802800U74-N September 2009
Summary of Contents for DIMETRA MTS 2
Page 4: ...This page intentionally left blank ...
Page 28: ...List of Procedures This page intentionally left blank xxii 6802800U74 N September 2009 ...
Page 30: ...List of Processes This page intentionally left blank xxiv 6802800U74 N September 2009 ...
Page 486: ...This page intentionally left blank A 10 6802800U74 N September 2009 ...
Page 492: ...This page intentionally left blank B 6 6802800U74 N September 2009 ...
Page 496: ...This page intentionally left blank C 4 6802800U74 N September 2009 ...