Chapter 2 Test Equipment, Service Aids, and Service
Tools
2.1
Test Equipment
Table 2-1 lists test equipment required to service the radios.
Table 2-1. Recommended Test Equipment
Motorola Part No.
Description
Characteristics
Application
R2600 series or
HP 8920A
System analyzer
This item will substitute for
items with an asterisk (*)
Frequency/Deviation meter and
signal generator for wide-range
troubleshooting and alignment
*R1074A
Fluke 87 digital
multi-meter
True RMS metering,
200 kHz frequency
counter, 32-segment bar
graph with backlit display
Digital voltmeter is recommended
for AC/DC voltage and current
measurements
Fluke 85 RF probe
500 MHz, 30 VAC max
Use with Fluke 87 digital
multi-meter for RF voltage
measurements.
*R1377A
AC voltmeter
1 mV to 300 mV, 10 mega-
Ohm input impedance
Audio voltage measurements
R1611A
Dual channel
100 MHz
oscilloscope
(Agillent)
Two-channel, 100 MHz
bandwidth, 200 M sample
rate/sec, 2 MB memory/
channel
Waveform measurements
S1339A
RF millivolt meter
100
μ
V to 3V RF, 10 kHz to
1 GHz frequency range
RF level measurements
*R1013B or
*R1370A
SINAD meter or
SINAD meter with
RMS
Without RMS audio
voltmeter or
With RMS audio voltmeter
Receiver sensitivity
measurements
Summary of Contents for CP Series
Page 1: ...Portable Radios Detailed Service Manual EP350 ...
Page 2: ......
Page 8: ...iv Notes ...
Page 18: ...xiv Notes ...
Page 26: ...Notes 2 4 Test Equipment Service Aids and Service Tools Service Aids ...
Page 72: ...7 26 Notes ...
Page 110: ...10 23 Notes ...
Page 153: ......