BT100 Installation and Operation Manual
Appendix A
Specifications
Specifications are valid over the given bandpass and operating temperature range of
−
40
°
F to
+140
°
F (
−
40
°
C to +60
°
C). Specifications are stated typical unless otherwise noted, and are
subject to change. Refer to the Motorola CHS web site or contact your account representative for
the latest specifications.
Model BT100
Specification Forward
Amplifier
Passband
52 through 1003 MHz
Gain
Full
46 dB (with SFE-*-*)
Operational
42 dB (with SFE-*-* and slope reserves)
Flatness
52 through 1003 MHz
±0.70 dB maximum
Level control, automatic
Bode board using ADU/QADU/TDU
Gain control
Fixed pads, JXP-
∗
B
Performance - reference frequency
(MHz)
1003/550/52
At typical output (dBmV)
45/44/37
Channels
79 analog/320 MHz
digital (suppressed by
6 dB)
Crossmod (worst case)
–66 dB
CTB (worst case)
–75 dB
CSO (worst case)
–71 dB
Noise figure
At 52 MHz
10 dB (with SFE-1)
At 1003 MHz
10 dB (with SFE-1)
Interstage equalizer, BDR-1G
14
±
1 dB
Hum modulation
–70 dB
Return loss, input/output
16 dB at operational level
Test points, input/output
20
±
1.0 dB
Housing dimensions
21.6 L
×
10.6 W
×
7.7 D inches (54.9
×
26.9
×
19.6 cm)
Weight
27 pounds (12.25 kg)