10A
10B
EN
EN
P5 - P6
05. FUNCTIONS
P1 - P2 - P3 - P4
05. FUNCTIONS
TIME ADJUSTMENT
This menu allows you to define the slowdown time for each sheet when
opening and closing.
Note •
Whenever there is a reversal of the direction of travel, the preset
deceleration time is increased by 2 sec. up to a maximum of 25 sec.
DEFAULT
VALUE
MIN
VALUE
MAX
VALUE
03
00
45
01
• Press
MENU
until it appears
[dA]
.
02
• Use
UP
or
DW
to navigate the parameters
[dA]
and
[dF]
.
03
• Press
MENU
to edit the value.
04
• Use
UP
and
DW
to change the value.
05
• Press
MENU
for 2sec. to save the new value.
FORCE ADJUSTMENT
This menu allows you to define the force that is injected into the engine when
it moves at normal speed.
DEFAULT
VALUE
MIN
VALUE
MAX
VALUE
06
00
09
01
• Press
MENU
until it appears
[F0]
.
02
• Press
MENU
to edit the value.
03
• Use
UP
and
DW
to change the value.
04
• Press
MENU
for 2sec. to save the new value.
PEDESTRIAN COURSE TIME
This menu allows you to set the pedestrian travel time.
DEFAULT
VALUE
MIN
VALUE
MAX
VALUE
10
00
99
01
• Press
MENU
to edit the value.
02
• Use
UP
and
DW
to change the value.
03
• Press
MENU
for 2sec. to save the new value.
PAUSE TIME
Allows to set the pause time at total opening.
Allows to set the pause time at the pedestrian opening.
DEFAULT
VALUE
MIN
VALUE
MAX
VALUE
10
00
99
01
• Press
MENU
until it appears
[AF].
02
• Use
UP
or
DW
to navigate the parameters.
03
• Press
MENU
to edit the value.
04
• Use
UP
and
DW
to change the value.
05
• Press
MENU
for 2sec. to save the new value.
PHOTOCELLS 1 PROGRAMMING
This menu allows you to program the LE safety behavior (photocell 1).
Enable or disable photocells
Define whether this security will act when opening or closing the gate.
(00 - acts on closing / 01 - acts on opening)
Define the behavior that the gate will have when this security is activated.
When safety is activated, the direction of movement of the gate is
reversed
When the security is activated, the movement of the gate stops.
When security is activated, the movement of the gate reverses for 2 sec.
is for. The movement is not resumed automatically.
LE
DEFAULT
VALUE
LE
OFF
LE
ON
00
00
01
HC
DEFAULT
VALUE
HC
CLOSE
HC
OPEN
00
00
01
HL
DEFAULT
VALUE
FUNCTIONS
HL
00
00 | 01 | 02
01
• Press
MENU
until it appears
[LE]
.
02
• Use
UP
or
DW
to navigate the parameters.
03
• Press
MENU
to edit the value.
04
• Use
UP
and
DW
to change the value.
05
• Press
MENU
for 2sec. to save the new value.
PHOTOCELLS 2 PROGRAMMING
This menu allows you to program the LA safety behavior (photocell 2).
Enable or disable photocells 2.
Define whether this security will act when opening or closing the gate.
(00 - acts on closing / 01 - acts on opening)
Define the behavior that the gate will have when this security is activated.
When safety is activated, the direction of movement of the gate is
reversed
When the security is activated, the movement of the gate stops.
When security is activated, the movement of the gate reverses for 2 sec.
is for. The movement is not resumed automatically.
Enable or disable the Stop push button function
LA
DEFAULT
VALUE
LA
OFF
LA
ON
00
00
01
HC
DEFAULT
VALUE
HC
OFF
HC
ON
01
00
01
HL
DEFAULT
VALUE
FUNCTIONS
HL
02
00 | 01 | 02
HE
DEFAULT
VALUE
HE
OFF
HE
ON
00
00
01
01
• Press
MENU
until it appears
[LA]
.
02
• Use
UP
or
DW
to navigate the parameters.
03
• Press
MENU
to edit the value.
04
• Use
UP
and
DW
to change the value.
05
• Press
MENU
for 2sec. to save the new value.