03. INSTALLATION
EMERGENCY RELEASE
FINAL CONSUMERS AND SPECIALIZED INSTALLERS INSTRUCTIONS
Place the key (C) supplied, in the hole
(V), which is located in the lever L1 and
turn it.
Insert, regulate and block the mechanical limit switches in the desired position.
04. TROUBLESHOOTING
LIMIT SWITCHES ASSEMBLY (OPTIONAL)
Closing
Opening
Problem
Probable cause
Solution
• With a remote control or key
selector, the gate does not
open or the motor does not
work
• There is no 230V power
supply
• Check main switch
• Emergency STOP present
• Control selectors or remote
controls STOP. If you do not
use STOP, check the bridge at
the STOP contact input on the
control board
• Fuse blown
• Replace with one of same
value
• Motor(s) power cable
disconnected or defective
• Connect the cable to
appropriate terminal or
replace
• There is an obstacle between
the photocells or they do not
work
• Check the connection, remove
any obstacle
• The gate does not open with
a remote control, but works
with the key selector
• The remote control has not
been memorised or the battery
is low
• Follow the remote control
recognition procedures on the
receiver or replace the battery
with a new one
• Gate starts to open/close, but
stops
• The force of the motor(s) is
insufficient
• Modify the value with the
FORCE button on the control
board
• One leaf opens and the other
closes
• The connection is not correct
• Change the polarity of the
motor cable that is working in
the opposite direction to the
correct one