ADJUSTMENT OF RADAR SENSITIVITY
This menu allows you to set the radar detection
sensitivity. The factory default is
[5]
.
MINIMUM
VALUE
>
FACTORY
VALUE
>
MAXIMUM
VALUE
1
2 3 4
5
6 7 8
9
01
• Press function key
[D]
.
02
• Press the numeric key to change the value.
03
• Press
#
to save the new value.
05. CONFIGURATION
05. CONFIGURATION
CONFIGURATION BY REMOTE CONTROL
CONFIGURATION BY REMOTE CONTROL
CONFIGURATION VALUES
FUNCTIONS
CONFIRMATION
RELAY OUTPUT
This menu allows you to set the status of the relay output (IR/Radar).
The factory value is
[3]
.
NO/NO
NO/NC
NC/NO
NC/NC
1
2
3
4
01
• Press function key
[A]
.
02
• Press the numeric key to change the value.
03
• Press
#
to save the new value.
DIRECTION DETECTION
This menu prevents the sensor from detecting an object that moves
away from the sensor. Factory default is
[1]
.
Nota •
A deteção de direção infravermelho (IR) funciona apenas
quando todos os IR pontos de deteção estão ativos. (5x12 pontos)
BOTH
APPROX.
ONLY
APPROX.
JUST GO
APPROX.
RADAR
ONLY
1
2
3
4
01
• Press function key
[B]
.
02
• Press the numeric key to change the value.
03
• Press
#
to save the new value.
CROSS TRAFFIC
This menu prevents the sensor from detecting movement parallel to
the door. Factory default is
[1]
.
Note •
Infrared (IR) direction detection works only when all IR
detection points are active.
OFF
ON
IR ON
RADAR
ON
1
2
3
4
01
• Press function key
[C]
.
02
• Press the numeric key to change the value.
03
• Press
#
to save the new value.
IR
IR
IR
IR
IR
IR
IR
IR
RADAR
RADAR
RADAR
RADAR
RADAR
RADAR
RADAR
RADAR
ATTENTION:
• If the
[1-9]
button is not pressed and the
[#]
button is pressed, the last selected
[1-9]
button becomes valid.
• When the
[#]
button is pressed after pressing the
[1-9]
button, the setting is confirmed
and saved.
• The last function selected on the remote control is the one that will be changed when
the
[1-9]
buttons are pressed.
(example:
[C]
followed by
[2]
sets Cross Traffic ON)
• If you press the
[#]
button without pressing the
[1-9]
button, it will exit the setting state
without any settings being saved.