background image

6

LEDs

MENU INC

DEC

GND

GND

OP-L

OP-R

CO

M

VC

C

ZER
O

P+

P-

GND

G

R

v+

12v

GND

M1

24V

M2

24V

+24v

GND

G

R

+12v

LEDs

GND

G

R

+12v

NC

ON

1 2 3 4 5 6 7 8

NORMAL

RESET

POWER LED

ID

JP11

JP11

JP12

JP12

T2

INITIAL

WIEGAND

ALARM2

LED

DOOR2

LED

ALARM1

LED

DOOR1

LED

NO

NC

NO

NC

NO

NC

NO

NC

GND

CASE4

CASE3 CASE2

PUSH2

PUSH1

CASE1 SENSOR

2

ALARM

2-

ALARM

2+

DOOR

2-

DOOR

2+

ALARM

1-

ALARM

1+

DOOR

1-

DOOR

1+

SENSOR

1

GND

GND

GND

GND

+12V

NORMAL

RESET

POWER LED

JP11

JP11

JP12

JP12

T2

INITIAL

WIEGAND

ALARM2

LED

DOOR2

LED

ALARM1

LED

DOOR1

LED

NO

NC

NO

NC

NO

NC

NO

NC

GND

CASE4

CASE3 CASE2

PUSH2

PUSH1

CASE1 SENSOR

2

ALARM

2-

ALARM

2+

DOOR

2-

DOOR

2+

ALARM

1-

ALARM

1+

DOOR

1-

DOOR

1+

SENSOR

1

GND

GND

GND

GND

+12V

ON

1 2 3 4 5 6 7 8

COM3

COM3

232

COM2

NORMAL

RESET

POWER LED

ID

JP11

JP11

JP12

JP12

T2

INITIAL

WIEGAND

COM2

COM1

COM1

COM1

COM2

COM3

+12V

+5V

JP1

READER

ALARM2

LED

DOOR2

LED

ALARM1

LED

DOOR1

LED

485

GND

GND

GND PWR

GND

DATA1

CLK1

ERR1

BZ1

DATA2

CLK2

PWR

DATA3

CLK3

DATA4

CLK4

485+

TXD1

485-

RXD1

TXD3

RXD3

OK2

OK1

ERR2

BZ2

COM3

COM3

232

COM2

NORMAL

RESET

POWER LED

JP11

JP11

JP12

JP12

T2

INITIAL

WIEGAND

COM2

COM1

COM1

COM1

COM2

COM3

+12V

+5V

JP1

READER

ALARM2

LED

DOOR2

LED

ALARM1

LED

DOOR1

LED

485

GND

GND

GND PWR

GND

DATA1

CLK1

ERR1

BZ1

DATA2

CLK2

PWR

DATA3

CLK3

DATA4

CLK4

485+

TXD1

485-

RXD1

TXD3

RXD3

OK2

OK1

ERR2

BZ2

EN

04. CONNECTIONS

DIAGRAM

Black

Black

Black

Black

Black

Red 

Red 

Red 

Blue (+)

Yell

ow  (-)

Yellow 

Yellow 

Blue

Yell

ow 

Green

Green

Right Arm

Solenoid

Access 

Controller

(

MRAC2000WSN

)

Input card

reader (ID1)

(

MPXR92MSK

)

RS488 cable

Output card

reader (ID2)

(

MPXR92MSK

)

Left Arm

Solenoid

Red 

Red 

Main Arm

 Solenoid 

(arm that falls in the 

event of a power 

failure)

The OP-L and OP-R connectors 

are left and right NO contacts, 

respectively. 

Summary of Contents for MTT03

Page 1: ...v3 0 REV 04 2021 MTT03 MTT03 EN USER S AND INSTALLER S MANUAL...

Page 2: ...sories eg Charger USB cable electronic material controls etc should not be disposed of as other household waste at the end of its useful life To avoid possible harm to the environment or human health...

Page 3: ...without any knowledge of the product provided that these are supervision and instructions given by persons with experienced in terms of usage of the product in a safe manner and who understands the ri...

Page 4: ...u the product manual and informed you how to handle the product in an emergency If the system requires any repair or modification unlock the automatism turn off the power and do not use it until all s...

Page 5: ...in both directions DIMENSIONS PACKING Inside the package you will find the following components 02 AUTOMATION 02 AUTOMATION TECHNICAL CHARACTERISTICS Dimensions in mm MTT03 Power supply 230 Vac Power...

Page 6: ...Turnstile users must not open the mechanism Maintenance and repair work should only be carried out by specialized personnel Unconscious interventions can lead to dangerous situations for the mechanis...

Page 7: ...JP12 JP12 T2 INITIAL WIEGAND COM2 COM1 COM1 COM1 COM2 COM3 12V 5V JP1 READER ALARM2 LED DOOR2 LED ALARM1 LED DOOR1 LED 485 GND GND GND PWR GND DATA1 CLK1 ERR1 BZ1 DATA2 CLK2 PWR DATA3 CLK3 DATA4 CLK4...

Page 8: ...ween functions 03 Press MENU to enter the desired function 04 Use DEC and INC to choose the desired value for the function 05 Press MENU to save the value After 5 seconds without button operation it w...

Page 9: ...e defective The damper bearing may be defective The damper must be adjusted as described in the manual If the damper is defective it must be replaced If the bearing is defective it must be replaced Th...