Motorline professional MPXR92MSWBE User& Installer'S Manual Download Page 7

6A

6B

1

7

EN

EN

01

01

02

02

03

04. DIP SWITCH

03. INSTALAÇÃO

DIP SWITCH CONFIGURATION

• RS485 OUTPUT AND POWER INPUT

WALL MOUNT

485 A (blue)

+12V (red)

GND (black)

485 B (yellow)

Mount the MPXR92MWSBE 

terminal on the back plate.

Attach the 

MPXR92MWSBE and 

the back plate using 

a star-shaped screw.

BOTTOM VIEW

Fix the back plate to the wall using the wall 

mount screws. (Use proper bushings for this 

purpose)

1

2

3

CABLE DESCRIPTION

For the control board to be able to identify the task of each of the readers interconnected in an 

access control system, it is necessary that each of these devices has a unique identification ID.

This ID is crucial to identify the task that each device performs and which port/access where 

it is installed.

The definition is made through the dip switch board on the back of each reader, according to 

the following table:

• If you connect two or more devices with the same ID to a control board, it will create a 

communication conflict and none will work properly.

ID

Dip switch

Door

Function

No ID

ON

1 2 3 4 5 6

-

-

1

ON

1 2 3 4 5 6

Door 1

Entry

2

ON

1 2 3 4 5 6

Exit

3

ON

1 2 3 4 5 6

Door 2

Entry

4

ON

1 2 3 4 5 6

Exit

5

ON

1 2 3 4 5 6

Door 3

Entry

6

ON

1 2 3 4 5 6

Exit

7

ON

1 2 3 4 5 6

Door 4

Entry

8

ON

1 2 3 4 5 6

Exit

Summary of Contents for MPXR92MSWBE

Page 1: ...V1 0 REV 02 2022 MPXR92MSWBE MPXR92MWSBE EN USER INSTALLER MANUAL...

Page 2: ...res duos separe estes itens de outros tipos de res duos e recicle os de forma respons vel para promover a reutiliza o sustent vel dos recursos materiais Os utilizadores dom sticos devem entrar em con...

Page 3: ...erstands the risks and dangers involved Children shouldn t play with the product or opening devices to avoid the motorized door or gate from being triggered involuntarily 01 SAFETY INSTRUCTIONS WARNIN...

Page 4: ...itions have been met In the event of tripping of circuits breakers of fuse failure locate the malfunction and solve it before resetting the circuit breaker or replacing the fuse If the malfunction is...

Page 5: ...h is part of the control and management of access to a given location TECHNICAL CHARACTERISTICS PRODUCT DESCRIPTION BASIC CONTENT 01 01 MPXR92MWBE 02 01 Metallic Rear Plate 03 02 Screw for Wall fixing...

Page 6: ...AND DIAGRAM OF PRODUCT CONNECTORS LED indicator 14 pin connectors RS485 energy input ID configurator Violation alarm button On the back of the mounting plate MIFARE Card Area Star shaped screw hole to...

Page 7: ...ccess control system it is necessary that each of these devices has a unique identification ID This ID is crucial to identify the task that each device performs and which port access where it is insta...

Page 8: ...k Recommended power supply 12Vdc 10 at least 500mA Comply with the IEC EN 60950 1 standard To share power with other devices use a power supply with higher current ratings N PIN DESCRIPTION WIRE 1 12V...

Page 9: ...department 07 TROUBLESHOOTING 06 TESTE DE COMPONENTES INSTRUCTIONS FOR CONSUMERS SPECIALIZED TECHNICIANS DEVICE TEST To avoid touch sensor self detection interference please do not touch the sensor w...