background image

12A

12B

EN

EN

Remote Programming Operation (PGM ON):

• 

Press the buttons indicated in the image simultaneously for 10 

seconds and the flashing lamp will flash (the 1st free position appears 

in the display).

Each time you store 1 remote control, the control board will exit remote 

programming. If you want to memorize more remote controls, you 

will always have to repeat the process of pressing the remote control 

buttons simultaneously for 10 seconds for each new remote control.

01 

• Press MENU for 2 sec. until it appears  . 

02 

• Use UP until appears  . 

03 

• Press Menu will appear  .  

04 

• Press MENU to edit the value.

05 

• Use UP and DW to change the value.

06 

• Press MENU to save the new value.

00 (disables human present)

Whenever an order is sent to the 

LO input and the motor performs a 

complete maneuver.

Man present

01 (active human present)

The motor only works if you keep 

the LS button pressed.

With the man present active

the RF remote controls do not work.  

00 (disables pushbutton mode)

01 (active pushbutton mode)

Allows you to define how the LS 

input works.

00 (disables input to 

emergency stop device)

01 (input for emergency stop 

devices)

If you have the LS submenu in 01 

(active) and the PL submenu in 01 

(active), the error appears 

.

Default value (

00

)

LS

LO

01

ON

Full

closing

Full 

opening

00

OFF

Pedestrian

maneuvers

Total

maneuvers

01 

• Press MENU for 10 sec. until it appears 

02 

• Press MENU until it appears 

. Use UP or DW to navigate the parameters.  

03 

• Press MENU to edit the chosen parameter value.

04 

• The factory set time appears. Use UP and DW to change the value.

05 

• Press MENU to save the new value.

00 human presence

01 function activated

This menu allows activate/disable soft start.

With the soft start function activated, at each start of movement, the control board will control 

the start of the motor, gradually increasing in the first second of operation.

Default value (

00

)

01 

• Press MENU for 10 sec. until it appears 

02 

• Use UP until appear 

03 

• Press Menu will appear 

.  

04 

• Press MENU to edit the value.

05 

• Use UP and DW to change the value.

06 

• Press MENU to save the new value.

01 

• Press MENU for 10 sec. until it appears 

02 

• Use UP until appears       . 

03 

• Press Menu will appear       .  

04 

• Press MENU to edit the value.

05 

• Use UP and DW to change the value.

06 

• Press MENU to save the new value.

Allows to adjust the courtesy light time. The courtesy light is activated for the set time when the 

gate is in the closed, open and standing position.

The E2 menu will only be available in the case if the courtesy light function is activated in the 

P8 menu option 2 (see page 11B)

Default value (

00

)

 SOFT START

 COURTESY LIGHT TIME

 REMOTE PROGRAMMING

 HUMAN PRESENT

04. PROGRAMMING "P"

05. PROGRAMMING "E"

05. PROGRAMMING "E"

05. PROGRAMMING "E"

Summary of Contents for MC62

Page 1: ...v1 5 REV 02 2022 MC62 MC62 EN USER S AND INSTALLER S MANUAL...

Page 2: ...UNCTIONS MENU E P0 COURSE PROGRAMMING P1 DECELERATION TIME ADJUSTMENT E2 COURTESY LIGHT TIME P7 OPERATING LOGIC P4 PAUSE TIME AND DOORS DELAY E6 DECELERATION SPEED P2 FORCE AND SENSITIVITY ADJUSTMENT...

Page 3: ...ant Read all instructions carefully before beginning the installation usage procedures and keep this manual in a safe place that it can be consulted whenever necessary This product is intended for use...

Page 4: ...tral from the bottom If the automatism is to be installed at a height of more than 2 5m from the ground or other level of access the minimum safety and health requirements for the use of work equipmen...

Page 5: ...automation of 24V swing gates Power Supply 20 24V AC Flashing light s output 24VDC 4W Max RGB Flashing light s output 24Vdc 100mA Max Motor s output 24Vdc 2 x 120W Max Auxiliary accessories output 24V...

Page 6: ...on the display 04 Make a course programming menu P0 page 9A 05 If necessary adjust the deceleration time of the gate at opening and closing menu P1 page 10A 06 Adjust the gateforce and sensivity menu...

Page 7: ...n where you want to program the remote control SU or SP use PROGRAMMING REMOTE CONTROLS ERASE ALL THE REMOTE CONTROL ERASE REMOTE CONTROLS If you do not press any button for 10 sec the control board w...

Page 8: ...light 00 11B Remote programming Distance PGM OFF Distance PGM ON 00 11B MENU FUNCTION MAX MIN PROGRAMMABLE STATE FACTORY VALUE PAGE Human Present Desactivates human present Activates human present 00...

Page 9: ...G P FORCE AND SENSIVITY ADJUSTMENT DIRECTION OF DISPLAY ROTATION COURSE PROGRAMMING OF TWO MOTORS Normal rotation leaf 1 starts opening normal speed Slow rotation leaf 1 goes into opening slowdown slo...

Page 10: ...ax 25s 0s min max 25s 01 Press MENU for 2 sec until it appears 02 Use UP until appears 03 Press Menu will appear Use UP or DW to navigate the parameters 04 Press MENU to edit the chosen parameter valu...

Page 11: ...rder the movement is reversed Step by step mode 1st impulse OPEN 2nd impulse STOP 3rd impulse CLOSE 4th impulse STOP If it is fully open and timed it closes Condominium Mode Does not respond to orders...

Page 12: ...ull closing Full opening 00 OFF Pedestrian maneuvers Total maneuvers 01 Press MENU for 10 sec until it appears 02 Press MENU until it appears Use UP or DW to navigate the parameters 03 Press MENU to e...

Page 13: ...m current value provided by the control board 00 disable opening push 01 active opening push Allows you to activate the opening stroke ram 00 disables closing push 01 active closing push Allows you to...

Page 14: ...hundred thousand Continuous light Flashing light Default value 00 When resetting all factory values will be reset The memorized remote controls and the maneuver counter will always have the memorized...

Page 15: ...ocell Full opening button pressed Obstructed photocell Pedestrian opening button pressed In pause time Control board performs the opening course In time of pedestrian pause Control board performs the...

Page 16: ...w the same steps until you find all the problems B START SYSTEMS 1 Disconnect all wires connected to the START connector 2 If the LED turned OFF try reconnecting one device at a time until you find th...

Page 17: ...TIONS MAP Full Opening Partial Opening Flashing Lamp 12 24VD 4W Max Power Supply Transformer 230Vac or 110Vac 50 60Hz 120W Max Solar panel Electric Lock 12 24VDC 12W Max Photocell Set Antenna RGB flas...

Reviews: