Motorline professional MC112PR Use And Care Manual Download Page 2

1A

1B

1B

19B

18

7A

19A

6

15A

16A

8

15B

16B
17A

5A

10

4A
4A

9

4A

11

4B

13
14

5B

12

7B

EN

EN

02. PRODUCT

00.CONTENT

INDEX

DESCRIPTION OF PRODUCT

TECHNICAL CHARACTERISTICS

DIMENSIONS

COMPONENTS MAP

MR13- RECEIVER

FREQUENCY INVERTERS CONNECTIONS

FREQUENCY INVERTERS

ADJUSTMENT OF LIMIT SWITCHES

INSTRUCTIONS FOR CONSUMERS AND SPECIALIZED TECHNICIANS

FREQUENCY INVERTER CONNECTIONS

DIGITAL NUMERIC KEYBOARD

OTHER CONNECTIONS (MAGNETIC LOOP DETECTOR, RESISTOR AND PUSH BUTTON)

LOCK/UNLOCK KEYBOARD

MF2020

CONNECTIONS CONNECTORS

LED DISPLAY MESSAGES

MR13 RECEIVER CONNECTIONS

MENU NAVIGATION

CLOSING PRE- FLASHING LIGHT

UPS UNIT CONNECTION

RELAY FOR TWO-DOOR INTERLOCK

PROGRAMMING MENU ACCESS (MENU 04)

EXTERNAL COMPONENTS CONNECTIONS

PROGRAMMING MENU - 04

01. SAFETY INSTRUCTIONS

03. COMPONENTS

04. INVERTERS AND CONECTORS

07. PROGRAMMING

08. TROUBLESHOOTING

05. CONNECTIONS SQUEME

06. DESCRIPTIONS

01. SAFETY INSTRUCTIONS

This product is certified in accordance with European 

Community (EC) safety standards.

This product complies with Directive 2011/65/EU of the 

European Parliament and of the Council, of 8 June 2011, on 

the restriction of the use of certain hazardous substances in 

electrical and electronic equipment.

(Applicable in countries with recycling systems).

This marking on the product or literature indicates that the 

product and electronic accessories (eg. Charger, USB cable, 

electronic material, controls, etc.) should not be disposed 

of as other household waste at the end of its useful life. To 

avoid possible harm to the environment or human health 

resulting from the uncontrolled disposal of waste, separate 

these items from other types of waste and recycle them 

responsibly to promote the sustainable reuse of material 

resources. Home users should contact the dealer where they 

purchased this product or the National Environment Agency 

for details on where and how they can take these items 

for environmentally safe recycling. Business users should 

contact their vendor and check the terms and conditions 

of the purchase agreement. This product and its electronic 

accessories should not be mixed with other commercial 

waste.

This marking indicates that the product and electronic 

accessories (eg. charger, USB cable, electronic material, 

controls, etc.) are susceptible to electric shock by direct or 

indirect contact with electricity. Be cautious when handling 

the product and observe all safety procedures in this manual.

ATTENTION:

Summary of Contents for MC112PR

Page 1: ...V3 0 REV 08 2022 MC112PR MC113PR MC114PR EN USER S AND INSTALLER S MANUAL...

Page 2: ...estriction of the use of certain hazardous substances in electrical and electronic equipment Applicable in countries with recycling systems This marking on the product or literature indicates that the...

Page 3: ...enced in terms of usage of the product in a safe manner and who understands the risks and dangers involved Children shouldn t play with the product or opening devices to avoid the motorized door or ga...

Page 4: ...and do not use it until all safety conditions have been met In the event of tripping of circuits breakers of fuse failure locate the malfunction and solve it before resetting the circuit breaker or r...

Page 5: ...llows easy and intuitive operation of various parameters and menus through a display It also has other functions such as Human Presence possibility to view the count of cycles carried out by the door...

Page 6: ...g the operation LEDs LED 1 ON Indicates that it is being powered at 230Vac OFF No power LED 2 ON SEC contact closed OFF SEC contact open LED 3 ON STR contact closed OFF STR contact open LED 4 Programm...

Page 7: ...24V 9 S1 9 S2 15 DCM SG SG SGND 13 MCM 22 RC 7 RA 21 RB R L1 S L2 T L3 U T1 V T2 W T3 B2 2 B1 DC 1 DC 10 MI1 11 MI2 5 MI3 6 MI4 8 MI5 20 MI6 MI7 4 24V 4 24V 12 DCM 12 DCM DFM 16 10V 13 ACM 14 AVI 15 A...

Page 8: ...ACM Not used AVI Not used ACI Not used AFM Not used M01 Pulse output for MR13 M02 Output for optional interlocking relay or pre flashing light Programmable at parameter 04 61 MI1 Opening button MI2 Cl...

Page 9: ...CM ON 1 2 ANT STR SEC 12 13 N L R G B 4 2 1 6 11 10 3 5 7 8 9 N F 10 8 9 3 4 5 2 1 7 20 24 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 M1 M2 M3 OP C P COM FAP FCH COM DS BL GND 24V...

Page 10: ...13 MCM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 ON 1 2 ANT STR SEC 12 13 N L R G B 4 2 1 6 11 10 3 5 7 8 9 N F 19 14 13 12 17 21 11 12 18 22 M1 M2 M3 OP C P COM FAP FCH COM DS B...

Page 11: ...M 12 DCM DFM 16 10V 13 ACM 14 AVI 15 ACI 17 AFM 14 M01 15 M02 24V 9 S1 9 S2 15 DCM SG SG SGND 13 MCM 4 4 EN 05 CONNECTIONS SQUEME OTHER CONNECTIONS MAGNETIC LOOP DETECTOR RESISTOR AND PUSH BUTTON RESI...

Page 12: ...SG SGND 13 MCM ON 1 2 ANT STR SEC 12 13 N L R G B 4 2 1 6 11 10 3 5 7 8 9 N F M1 M2 M3 OP C P COM GND FAP FCH COM DS BL GND 24V BR2 R G B 12V E1 BR1 E1 N N L L NO COM 4 15 EN 05 CONNECTIONS SQUEME CLO...

Page 13: ...4 STR SEC 12 13 N L R G B M1 M2 M3 OP C P COM GND FAP FCH COM DS BL GND 24V BR2 N L N L E1 BR1 E1 N N L L IN 230V OUT 230V A1 A2 NC COM EN UPS UNIT POWER SUPPLY UPS POWER SUPPLY INPUT UPS POWER SUPPLY...

Page 14: ...5 M02 24V 9 S1 9 S2 15 DCM SG SG SGND 13 MCM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 ON 1 2 ANT STR SEC 12 13 N L R G B 10 8 9 M1 M2 M3 OP C P COM FAP FCH COM DS BL GND 24V BR2...

Page 15: ...C DC 12 24V LED COM NO AC DC 12 24V EN 05 CONNECTIONS SQUEME EXTERNAL COMPONENTS CONNECTIONS CONTROL BOARD CONNECTIONS CRANK SENSOR RADAR 1 RADAR 2 ELECTRIC BRAKE LIMIT SWITCH OPENING CLOSING LINE 1 L...

Page 16: ...erent display modes 7 STOP RESET Restarts the device after a failure occurs 8 ENTER Used to enter change programming parameters 3 and 4 cannot be used Only the menus on page 16A can be set by the user...

Page 17: ...1 Enter at parameter 00 07 and set password You will temporarily unlock the keyboard 2 Change the parameter you want The release will remain until the motor make a new operation WRONG PASSWORD 1 You h...

Page 18: ...ex 10 1 sec 15 Parameter Function Settings Factory Setting 04 57 PEDESTRIAN OPENING TIME This menu can select the length of the pedestrian opening Knowing that 100 means 8M if put 12 means opening of...

Page 19: ...ton or a previously programmed remote control when you want the opening slowdown to start the speed automatically reduces Press the OP button or a previously programmed remote control when you want th...

Page 20: ...ation time too short Increase the acceleration time OVERCURRENT DURING DECELERATION 01 Short circuit at the motor output Check that the isolation on the output lines is in good condition DETECTION OF...

Reviews: