8A
8B
NO
NC
COM
19
18
19
18
P
Q
U
R
S
T
EN
EN
03. INSTALLATION
03. INSTALLATION
CONTROL BOARD FIXATION
LIMIT-SWICHES ADJUSTMENT
1
• Determine the drilling location.
2
• Make the drilling in the wall.
3
• Fix the control board case on the wall. Must use screws with expansion bolts (screws and
expansion bolts not provided in this kit).
NOTE
• The red ring must activate it’s micro-switch
by the bottom and the white ring must do it by the
top, as shown in the picture to the left.
Microswitch connections:
1
•
Manually put the door in the desired opening position using the handcrank.
2
•
Rotate the tuning screw 18 (red) until the red ring of the limit-switch activates the correspondend
micro-switch.
3
•
Manually put the door in the desired closing position using the handcrank.
4
•
Turn the tuning screw 19 (white) until the white ring of the limit-switch activates the
correspondend micro-switch.
red
open
white
close