and adjust cycle accordingly.  The drain should remain open long enough the discharge accumulated water but not much longer.  Too long a drain time 
will waste energy and too short a time will allow excessive water to accumulate. 
 

Manual Override:

  A manual override switch (3) is located on the front of the unit.  Activating this switch will place the solenoid valve in a continuously 

open position.  The switch will glow red when in the on (valve open) position. 

 

 
WARNING:  Completely relieve all pressure from the system before attempting to service the drain.  Disconnect drain unitt from all external 
sources of pressure and electrical power.  Employ approved lockout/tagout devices while working on the system.  Failure to follow these 
directions can result in serious personal injury and death. 
 

The Automatic Drain will provide years of service if it is regularly and properly maintained.  The following procedure should be performed on a 

monthly 

basis:  

1. 

Disconnect electrical supply and depressurize Drain as instructed above. 

2. 

Remove Drain and flush the solenoid inlet and outlet ports with a safe oil-cutting detergent such as 

Lestoil

 or

 Fantastic

.  Take 

care that water and detergent is kept away from all electrical components

.  Do not remove cover or submerge unit in liquid.  

Failure to follow this warning may result in serious injury, death and property damage.

 

3. 

Remove plug on Wye strainer assembly, remove and clean screen with detergent.  Reassemble strainer. 

4. 

Replace the drain and reconnect power. 

 

                      
 

 

 

 

 

 

 

 

 

Replacement Parts 

 

 

 

 

 

 

 

 

 

 

Solenoid Disassembly:

  If the drain is bleeding air continuously and the override switch is 

in the closed position it may be necessary to disassemble the solenoid valve to clear the 
seat of foreign materials. 
 
 

Tools Required: 

1. 

Small Slotted Screwdriver 

2. 

#2 Phillips Screwdriver 

3. 

Small Adjustable Crescent Wrench 

 

1. 

Disconnect Drain from external pressure and power sources as directed above. 

2. 

Remove cover by removing (4) screws. 

3. 

Whole holding body of valve, remove hex nut which retains solenoid valve to coil.  Note orientation of valve so that it may be reinstalled in the 
same manner. 

4. 

Remove stem assembly by carefully turning stem CCW.  Do not strike or twist the stem with any object, as doing so will damage it. 

5. 

Inspect the valve seat and carefully remove and foreign material. 

6. 

Inspect the plunger assembly and remove any foreign material.  Safe detergent may be used here. 

7. 

Reassemble solenoid and valve by reversing the above procedures.  Take care that the actuator cover is carefully aligned over the pin and 
that the outer cast portion is positioned on the outer side of the solenoid. 

8. 

Reassemble solenoid and coil, taking care to orient valve correctly in flow direction. 

 

 

 

Motor  Guard  Corporation  assumes  the  responsibility  of  providing  equipment  that  is  free  from  defects  in  workmanship  and  material.    Should  this  product  fail  due  to  a  defect  in 
workmanship or material, Motor Guard Corporation will repair or, at its option, replace the product without charge, other than the transportation charges, provided that the product is 

returned to the factory, transportation prepaid, within one year of the date of purchase.  Please contact Motor Guard Corporation for return authorization and shipping instructions. 
 

This limited warranty does not cover damage to the product due to neglect, misuse or accident, nor does it cover any loss, damage or expense, either direct, indirect or consequential, 
arising from the non-function of this product.  This limited warranty notice replaces any other warranty information, implied or otherwise, enclosed with this product or appearing in 

literature referring to this product. 

 

         

MAINTENANCE    

.

    

 

 

Key 

Part No 

Description 

VK5702 

Solenoid Valve Kit with Coil and Wire 
Terminals 

PK5700 

Power Cord Kit with Strain Relief and Wire 
Terminals 

SK5700 

Switch Kit with Wire Terminals 

TK5700 

Timer Board Kit with Knobs, Mounting Screws 
and Terminals 

CK5700 

Solenoid Coil Kit with Wire Terminals 

RF2035 

Wye Strainer with Screen 

SSK202 

Replacement Screen for Wye Strainer 

         

LIMITED WARRANTY   

.

    

 

 

Reviews: