background image

 

Turning

 

the

 

Inverter

 

Off

 

Between

 

Uses

 

The

 

Mobile

 

Digital

 

Power

 

Inverter

 

draws

 

less

 

than

 

2

 

A

 

from

 

the

 

battery

 

with

         

the

 

ON/OFF

 

switch

 

turned

 

on

 

and

 

no

 

load

 

connected,

 

but

 

left

 

in

 

this

 

state

       

the

 

Mobile

 

Digital

 

Power

 

Inverter

 

will

 

eventually

 

discharge

 

the

 

battery.

     

To

 

prevent

 

unnecessary

 

battery

 

discharge,

 

turn

 

the

 

Mobile

 

Digital

 

Power

 

Inverter

   

off

 

when

 

you

 

are

 

not

 

using

 

it.

   

Operating

 

Limits

 

 

Power

 

Output

 

The

 

Mobile

 

Digital

 

Power

 

Inverter

 

can

 

deliver

 

up

 

to

 

1500

 

W

 

continuous.

   

The

 

wattage

 

rating

 

applies

 

to

 

resistive

 

loads

 

such

 

as

 

incandescent

 

lights.

 

 

Input

 

Voltage

                                         

The

 

allowable

 

Mobile

 

Digital

 

Power

 

Inverter

 

input

 

voltage

 

ranges

 

are

 

shown

 

in

 

the

 

following

 

table.

 

 

Operating

 

Condition

   

Voltage

 

Range

 

Comment

 

Normal

 

11.0

 

V–15.0

 

V

 

 

Optimum

 

Performance

 

12.0

 

V–13.0

 

V

 

 

Low

 

Voltage

 

Alarm

 

10.5

 

V

11.5

 

V

 

The

 

low

 

battery

 

alarm

 

sounds

 

Low

 

Voltage

 

Shutdown

 

10.0

 

V

11.0

 

V

 

The

 

inverter

 

shuts

 

down

 

to

 

protect

 

the

 

battery

 

from

 

being

 

over

discharged

 

High

 

Voltage

   

Shutdown

 

15.0

 

V

16.3

 

V

 

 

The

 

inverter

 

shuts

 

down

 

to

 

protect

   

itself

 

from

 

excessive

 

input

 

voltage.

 

Note:

 

Although

 

the

 

Mobile

 

Digital

 

Power

 

Inverter

 

incorporates

 

over

voltage

 

protection,

 

it

 

can

 

still

 

be

 

damaged

 

if

 

input

 

voltage

 

exceeds

 

16.3

 

V.

 

 

Inverter

 

Loads

 

The

 

Mobile

 

Digital

 

Power

 

Inverter

 

will

 

operate

 

most

 

AC

 

loads

 

within

 

its

 

power

 

rating

 

of

 

1500

 

W.

 

However,

 

some

 

appliances

 

and

 

equipment

 

may

 

be

 

difficult

 

to

 

operate,

 

and

 

other

 

appliances

 

may

 

actually

 

be

 

damaged

 

if

 

you

 

try

 

to

 

operate

 

them

 

with

 

the

 

Mobile

 

Digital

 

Power

 

Inverter.

 

Please

 

read

 

“High

 

Surge

 

Loads”

 

and

 

“Trouble

 

Loads”

 

carefully.

 

 

High

 

Surge

 

Loads

 

Some

 

induction

 

motors

 

used

 

in

 

freezers,

 

pumps,

 

and

 

other

 

motor

operated

 

equipment

 

require

 

high

 

surge

 

currents

 

to

 

start.

 

The

 

Mobile

 

Digital

 

Power

 

Inverter

 

may

 

not

 

be

 

able

 

to

 

start

 

some

 

of

 

these

 

motors

 

even

 

though

 

their

 

rated

 

current

 

draw

 

is

 

within

 

the

 

inverter’s

 

limits.

 

The

 

Mobile

 

Digital

 

Power

 

Inverter

 

will

 

normally

 

start

 

single

phase

 

induction

 

motors

 

rated

 

at

 

1/2

 

horsepower

 

or

 

less.

 

Note:

 

Although

 

the

 

Inverter

 

can

 

supply

 

momentary

 

surge

 

power

 

up

 

to

 

3000

 

W,

 

some

 

appliances

 

may

 

exceed

 

the

 

capabilities

 

of

 

the

 

Inverter

 

and

 

trigger

 

the

 

safety

 

 10

Summary of Contents for ELIMINATOR 299-5299-0

Page 1: ...Mobile Digital Power Inverter 299 5299 0 Owner s Manual TOLL FREE HELPLINE 1 877 466 8191 ...

Page 2: ...ult in a risk of fire electric shock or injury to persons 4 To avoid a risk of fire and electric shock make sure that existing wiring is in good condition and that wire is not undersized Do not operate the Mobile Digital Power Inverter with damaged or substandard wiring 5 Do not operate the Mobile Digital Power Inverter if it has received a sharp blow been dropped or otherwise damaged in any way I...

Page 3: ...ith lead acid batteries Lead acid batteries produce a short circuit current high enough to weld metal to skin causing a severe burn 6 Have someone within the range of your voice or close enough to come to your aid when you work near a lead acid battery 7 Have plenty of fresh water and soap nearby in case battery acid contacts skin clothing or eyes 8 Wear complete eye protection and clothing protec...

Page 4: ... be plugged directly into an AC receptacle to recharge Some chargers for battery packs used in power hand tools These affected chargers display a warning label stating that dangerous voltages are present at the battery terminals If you are unsure about using your rechargeable appliance with the Mobile Digital Power Inverter contact the equipment manufacturer to determine the rechargeable appliance...

Page 5: ...ration 9 Turning the Inverter On and Off 9 Operating Several Loads at Once 9 Turning the Inverter Off Between Uses 10 Operating Limits 10 Power Output 10 Input Voltage 10 Inverter Loads 10 High Surge Loads 10 Trouble Loads 11 Mobile Digital Power Inverter unit 11 5 Troubleshooting 12 Buzz in Audio Equipment 12 Television Reception 12 Troubleshooting Reference 12 A Specifications 14 Electrical Perform...

Page 6: ...d the inverter will draw less than 2A Please turn the inverter off when not in use to prevent unnecessary battery discharge The remote control will function when the power switch on the Mobile Digital Inverter is in the off position It will not function when the switch is turned on Make sure the remote control cable is connected to the inverter securely and the switch is off before operating the r...

Page 7: ...ture protects the battery from being completely discharged High battery voltage shutdown shuts the Mobile Digital Power Inverter down automatically if the input voltage rises to 15 V 16 3 V Overload shutdown shuts the Mobile Digital Power Inverter down automatically if a short circuit is detected in the circuitry connected to the inverter s output or if the loads connected to the inverter exceed t...

Page 8: ... switch turns the inverter s control circuit on and off This switch is not a power disconnect switch Disconnect AC and DC power before working on any circuits connected to the inverter 2 Power light is a green light indicating the ON OFF switch is on and AC voltage is present at the inverter s AC outlets 3 Fault light is a red light indicating the inverter has shut down due to low or high battery ...

Page 9: ... Output 5 V 2 1 A charge DC Panel 1500 W Figure 2 2 DC Panel Feature Description 1 Negative DC Cabling Terminal always connects to the battery cable that is connected to the negative terminal of the battery 2 Positive DC Cabling Terminal always connects to the battery cable that is connected to the positive terminal of the battery 3 Ventilation Opening must not be obstructed for the proper operati...

Page 10: ... purchase as much battery capacity as possible CAUTION The Mobile Digital Power Inverter must only be connect to a 12 V battery system It will not operate if connected to a 6 V battery and will be damaged if connected to a battery with 16 V or more Choosing an Apporiate Location WARNING Explosion or fire hazard The Mobile Digital Power Inverter contains components that tend to produce Arcs or spar...

Page 11: ...re resistance and therefore voltage drop is less and the cost is lower Protected from Do not mount the inverter where it will be exposed to gases battery gases producted by batteries Battery gases are corrosive and prolonged exposure to battery gases will damage the inverter Calculating Cable Sizes To operate safely and effectively the Mobile Digital Power Inverter needs proper cables and fuses Be...

Page 12: ...will secure the cables to the battery to the disconnect battery selector switch and the fuse block The connectors you use must create a permanent low resistance connection If crimp connectors are required MotoMaster recommends using approved and certified connectors and to use the tool recommended by the terminal manufacturer Make sure no stray wires protrude from the connector or terminal 4 For e...

Page 13: ...en the nut on the DC input terminals Damage to the DC input terminals may result The maximum torque setting is 10 ft lb 13 6 N m CAUTION Reverse Polarity DC power connections to the Mobile Digital Power Inverter must be positive to positive and negative to negative A reverse polarity connection positive to negative will blow fuses in the inverter and may permanently damage the inverter The fuses a...

Page 14: ... display zero for power out this is normal Please double check that the small load device is working as expected if the display shows a zero Please contact our customer support for questions at 1 877 466 8191 CAUTION The remote control will function when the power switch on the Mobile Digital Inverter is in the off position It will not function when the switch is turned on Make sure the remote con...

Page 15: ...Shutdown 15 0 V 16 3 V The inverter shuts down to protect itself from excessive input voltage Note Although the Mobile Digital Power Inverter incorporates over voltage protection it can still be damaged if input voltage exceeds 16 3 V Inverter Loads The Mobile Digital Power Inverter will operate most AC loads within its power rating of 1500 W However some appliances and equipment may be difficult ...

Page 16: ...kitchen appliances and other loads may be damaged Some chargers for small rechargeable batteries can be damaged See Precautions for Using Rechargeable Appliances for details Metal halide arc HMI lights can be damaged Important If you are unsure about powering any device with the Mobile Digital Power Inverter contact the manufacturer of the device Mobile Digital Power Inverter unit Minimal maintena...

Page 17: ...e with television reception on some channels If interference occurs try the following 1 Make sure that the television antenna provides an adequate snow free signal and that you are using good quality cable between the antenna and the television 2 Keep the cables between the battery and the Mobile Digital Power Inverter as short as possible and twist them together with two to three twists per foot ...

Page 18: ...urning the inverter is provided in the Warranty section Problem Possible Cause Solution No output voltage Fault light is on Low input voltage High input voltage Thermal shutdown Unit overload Output is short circuited Recharge the battery check the connections and cable Make sure the Mobile Digital Power Inverter is connected to a 12 V battery check the voltage regulation of the charging system Al...

Page 19: ...d 12 V DC input Maximum continuous output power Maximum surge power 1500 W 3000 W Output voltage 120 V AC RMS Output waveform Modified sine wave Output frequency 60 1 Hz Input voltage 11 0 15 0 V DC Nominal current at full load 115A Maximum input current Peak 230A Low voltage alarm 10 5 V 11 5 V Low voltage cut out 10 0 V 11 0 V Optimum efficiency 90 No load current draw 2 A DC Physical Specificat...

Page 20: ...tandard practices This warranty covers any defects in workmanship or materials How long does coverage last This warranty lasts for 12 months from the date of purchase What does this warranty not cover This warranty will not apply when the product has been misused neglected improperly installed physically damaged or altered either internally or externally or damaged from improper use or use in an u...

Page 21: ...pe of installation e g RV truck vehicle ___________________________ Length of time inverter has been installed____________________________ Battery battery bank size ______________________________ DC wiring size and length______________________________ Appliances operating when problem occurred __________________________ Description of problem ______________________________ ________________________...

Reviews: