background image

TROUBLESHOOTING

11

model no. 011-2047-2  |  contact us : 1-877-466-8191

12

WARRANTY

TROUBLESHOOTING

PROBLEM: Low or No Output Voltage – Fault LED Lit

Reason

Solution

Poor contact with battery, inverter 

terminals.

Clean terminals thoroughly. Reinstall 

and tighten.

PROBLEM: Inverter Auto Shut Down – Fault LED Lit

Reason

Solution

Battery voltage is below 10.0 volts.

Charge or replace battery.

Inverter is too hot (thermal shut down 

mode).

Allow inverter to cool.

C heck for adequate ventilation.

Reduce the load on the inverter to

the specified TrueRated

TM

 power

max output.

PROBLEM: Inverter Shut Down – Fault LED Lit

Reason

Solution

Equipment being operated draws too 

much power.

Do not use the equipment with this 

inverter; use a higher wattage inverter.

PROBLEM: No AC Output – Yellow Ground Fault LED Lit

Reason

Solution

Ground fault is unintended AC current 

that is flowing to ground. It can be 

caused by faulty wiring, bad insulation, 

very long wiring, and sparking 

appliances.

Turn inverter OFF (O) to reset it, then 

to ON (I). IF the inverter immediately 

shuts off, disconnect each appliance 

or wiring until the inverter will stay 

on after reset. Examine the wiring or 

appliance for unintended connections. 

Repair or replace as necessary.

PROBLEM: Continuous Buzzing Sound 

Reason

Solution

Input voltage is below 10.5 volts.  

       Keep input voltage above 10.5 volts. 

Poor or weak battery condition.  

       Recharge or replace battery. 

Poor or loose cable connection.  

       Inspect terminals and tighten all connections.   

Inadequate power being delivered to  
the inverter or excessive voltage drop. 

Made in China 
Imported by MotoMaster Canada, Toronto, Canada M4S 2B8

Electronic products are known to contain materials that are toxic if improperly 
disposed. Contact local authorities for disposal and recycling information. 

This MotoMaster

®

 Eliminator

®

 product carries a one (1) year warranty against defects

in workmanship and materials. At its discretion, MotoMaster Canada agrees to have any
defective part(s) repaired or replaced free of charge, within the stated warranty period, 
when returned by the original purchaser with proof of purchase. This product is not 
guaranteed against wear or breakage due to misuse and/or abuse.

DISPOSAL/RECYCLING OF INVERTER 

CONFORMS  TO  UL  STD.458

CERTIFIED  TO  CSD  STD. C22.2 NO.107.1

Summary of Contents for ELIMINATOR 011-2047-2

Page 1: ... SINE WAVE GF 2 1A SAVE THESE INSTRUCTIONS This manual contains important safety and operating instructions Read all instructions and follow them with use of this product Questions Call Customer Service Hotline 1 877 466 8191 model no 011 2047 2 ...

Page 2: ...ts allows the inverter to start most difficult motorized appliances Advanced microprocessor controlled circuits run cooler and are more reliable than competing units The Pure Sine 400 W operates at high efficiency up to 90 that results in long run time and extended battery life compared to other inverters with this level of power output A 2 1 A USB power port provides a convenient way to power USB...

Page 3: ...2 13 16 23 6 x 12 x 7 1 cm 2 lb 10 oz 1 2 kg 23 5 8 60 cm 11 AWG All specifications are typical at nominal line half load and 77 F 25 C unless otherwise noted Specifications are subject to change without notice INVERTER OUTPUT CAN BE LETHAL IMPROPER USE OF THIS INVERTER MAY RESULT IN PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE Keep the inverter away from any direct heat source or combustible m...

Page 4: ...tablets e readers smart phones and other small electronic devices Audible Alarm internal to the inverter When the Audible Alarm makes a buzzing sound the inverter senses a low battery condition The user should reduce the AC load charge the battery and check the DC cable for excessive losses Positive Terminal Positive DC Input Red Negative Terminal Negative DC Input Black Cooling Fan High speed and...

Page 5: ...LED indicator is lit the inverter is signaling a fault Setting Up the Battery Connecting the Inverter WARNING EXPLODING BATTERIES Batteries that are used indoors or inside a vehicle or vessel should be deep cycle sealed lead acid batteries Exploding batteries can spray molten lead hot sulphuric acid and other metal and plastic fragments Batteries that are charging or under high discharge rates pro...

Page 6: ...wer source by running an extension cord from the inverter to the television Note If an extension cord is used from the inverter to the appliance limit the extension cord length to 100 30 m or less Make sure that the cord is safety approved and AWG 10 or greater to carry the appliance load Remember that extension cords are for temporary use WARNING THERE IS DANGER OF EXPLOSION DO NOT CONNECT OR DIS...

Page 7: ... shuts off disconnect each appliance or wiring until the inverter will stay on after reset Examine the wiring or appliance for unintended connections Repair or replace as necessary PROBLEM Continuous Buzzing Sound Reason Solution Input voltage is below 10 5 volts Keep input voltage above 10 5 volts Poor or weak battery condition Recharge or replace battery Poor or loose cable connection Inspect te...

Reviews: