Model no. 011-1974-0 l Questions? Contact us 1-888-942-6686
16
The battery does not
go into Maintenance
mode after being
charged for 24
hours.
Note: When F05
appears, disconnect
AC power and
remove clamps from
battery. Re-connect
and attempt to
charge again.
Try charging battery again using a
higher charge rate.
Remove any loads connected to the
battery during charging.
There is a load placed
on the battery while
charging.
Battery is defective and
will not accept a charge.
The battery clamps are
incorrectly connected.
Reverse polarity.
Replace battery.
Reverse clamp connections.
The charge current
is too low.
Error Code
Condition
Cause
Solution
Input Voltage AC
Working Voltage AC
Input Amps
Charging Voltage
Charging Current
Minimum Battery Voltage
Ambient Operating Temperature
Charger Type
Compatible Battery Voltage
Compatible Battery Types
Compatible Battery Capacities
Dimensions (L x W x H)
Weight
120 V AC, 60 Hz
104 127 V AC, 60 Hz
3.5 A (max.)
14.4 V
2/4/8 A
1.5 V
6-step, fully automatic
12 V (nominal)
All lead-acid (Wet, MF, Ca, AGM and Gel)
Charging: 10 to 160 Amp-hour
Maintenance: 10 to 400 Amp-hour
8 11/16 x 6 11/16 x 4 15/16" (22 x 17 x 12.5 cm)
2 lb 3 oz (1 kg)
TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS
TROUBLESHOOTING/FAULT CODES
-20
to 40 (-4 to 104 F).
C