![MOTO GUZZI V7 II ABS Service Station Manual Download Page 94](http://html.mh-extra.com/html/moto-guzzi/v7-ii-abs/v7-ii-abs_service-station-manual_1838150094.webp)
•
Take the measurement; The correct value is determined by subtracting the wire resistance
of the tester obtained by touching the two pins.
Example:
•
Resistance of stage 1 read on the display = 0.67 Ohm
•
Resistance of the wires read on the display = 0.47 Ohm
•
Effective resistance stage 1 = 0.67-0.47 = 0.20 Ohm
R
ESISTANCE
MEASURE
Winding stage
Ambient temperature (ohm)
Afterwards heat stabilisation (ohm)
Stage 1
0.18 - 0.23
0.20 - 0.25
Zero load voltage
Electrical system
V7 II ABS
ELE SYS - 94