32
15. TROUBLESHOOTING
No.
Problem Cause
Solution
1. Incorrect connection between
control panel and plug
Reconnect the 3-pin plug into the battery
connector on the side of the seat.
5
Charging Fault
2. Controller is damaged.
Contact customer service to replace the
controller.
3. Charger plug is damaged.
Contact customer service to replace the
charger plug.
4. Charging plug is loosened.
Recheck and firmly reconnect.
6
Fail to Start
When Power
On
After not using for a period or the
over-discharge protector is
activated.
Power on again after charging. If the problem
cannot be solved, please contact the
distributor to repair.
7
Unable to fold
Locking assembly
Check if there is something in the lock head
that causes the operation jam and can’t
move.
Front wheel interference
Check if the front wheel is caught in the frame
during folding.