Screen Descriptions
2-21
element
TM
Series
Table 2.3 Spare Outputs
Output
Description
NOT USED
This output is not currently assigned.
APS DONE
TAPS asserts this output when return is complete. Auxiliary power supply recall complete
ARROW DN
Turns ON when preferred direction of travel is below car’s present location. Down direction
preference arrow
ARROW UP
Turns ON when preferred direction of travel is above car’s present location. Up direction
preference arrow
BACKUP PWR
Battery lowering has been activated by the APS ON input (HAPS/TAPS)
CAR DELAY
Car has not been able to move, Typically due to doors being held open. Car delayed
CC REGSTRD
Car call registered. Activates for 1/2 second when a car call is registered.
CC SECURED
Activates for 1/2 second if a secured car call button is pressed.
CAR GONG
Car gongs
CAR LANTDN
Down car lanterns
CAR LANTUP
Up car lanterns
CLOSING
The doors are closing or attempting to close. See output DCF
DCF
Activates to close the doors. Turns off after door lock is established. Door close function
DHOLD END
Door hold function ending warning buzzer
DHOLD ON
Door hold function active
DOF
Turns ON to open the doors. Turns off after DOL opens. Door open function
EF GONG
Egress floor arrival gong
EMSC BUZZR
Emergency Medical Service car buzzer output
EMSC LIGHT
Emergency Medical Service car light output
EMSH LIGHT
Emergency Medical Service hall light output
EP CARDONE
Emergency power recall done output
EP LIGHT
Emergency power light. Flashes when car is selected to run on emergency power. Solid
when car is selected to recall.
EP LOBBY
Intended to drive a light at the designated emergency power return floor after the car is at
the floor with doors open on emergency power.
EP ON
Emergency power ON output
EP2 ON
Emergency Power Phase 2 run output active
EP SELECT
Emergency power car selected to recall or run output
EP1 ON
Emergency power lowering phase output
EP1 RECALL
Emergency power car selected to recall output
EP2 ON
Emergency power running phase output
EP2 RUN
Emergency power car selected to run output
EQ BUZZER
Turns ON after an earthquake has been detected. Earthquake buzzer
EQ LIGHT
Turns ON after an earthquake has been detected. Earthquake light
FAN LIGHT
Controlled by FLO Timer (Default 5 minutes) located in System Timers. Fan/light output
FLR GONG
Output activates when car passes a floor
FR HAT
Illuminates when we are on Fire Phase 1. Fire I hat light
FR ISV
In service for fire service light
FR RECALL
Fire recall light
FR1 BUZR
Fire I buzzer
FR1 DONE
Fire recall complete