Installation & Operation Manual

 

 

CONDOR SWING 

MA50777 Swing Control 

 

 

       

 

 
 
 

For Motion Access Condor Swing Operators 

 
 

 

 
 

MotionAccess, LLC 

775 Nicholas Blvd. 
Elk Grove Village, IL 60007 
847-357-8832

 

toll free: 866-357-8832 

fax: 847-357-8834 

www.MotionAccess.com 

[email protected]

 

 

Summary of Contents for CONDOR SWING MA50777

Page 1: ...ic entrance solutions Installation Operation Manual CONDOR SWING MA50777 Swing Control For Motion Access Condor Swing Operators MotionAccess LLC 775 Nicholas Blvd Elk Grove Village IL 60007 847 357 8832 toll free 866 357 8832 fax 847 357 8834 www MotionAccess com info MotionAccess com ...

Page 2: ...6 Never let children operate or play with door controls Keep the remote control where provided away from children 7 Personnel should keep away from a door in motion and keep the moving door in sight until it is completely closed or opened NO ONE SHOULD CROSS THE PATH OF A MOVING DOOR 8 Test the door s safety features once a day Have a trained door systems technician make any adjustments to the ope...

Page 3: ...and then connected to the power harness inside the header see Wiring Diagram on last page a Black Line Hot b White Neutral c Green Ground earth ground WARNING Supply earth ground should be connected to the green ground screw inside the operator header Severe injury or death may result if ground wire is not properly connected 5 Install required equipment into the door opening safety sensors activat...

Page 4: ...rnal jumper J2 must be in the correct position to permit High Energy programs All units are shipped as Low Energy unless specifically requested to be High Energy See the attached section Controller Settings Adjustments for details DANGER When using High Energy programs appropriate safety equipment must be in place See ANSI BHMA A156 10 and A156 19 standards 9 Select DIP switches See the attached D...

Page 5: ...The door may activate unexpectedly when power is restored DANGER Route harnesses away from moving parts sharp edges 11 Ensure you and others are clear of door s and mechanism 12 Connect power harness to controller and restore main power 13 Provide a continuous activation signal to the control or set the jamb function switch to Hold Open if available The spindle will rotate to the full open positio...

Page 6: ...vation terminals 16 and 17 see Wiring Diagram Or the door can also be activated by pushing the door slightly open 18 Always wait 5 seconds before reactivating after a sizing cycle 19 Using the thumb turn potentiometers adjust the door operation See the attached Potentiometer Adjustments table in the Controller Settings Adjustments section for details Doors should be adjusted to ANSI BHMA A156 10 a...

Page 7: ...m being mistaken as an obstruction and allows the full capabilities of the sensors to be used F G 12 Vac Power Supply Accessory Power Output terminals for accessory power Do not exceed 0 5 Amp H L N U W Y Commons Commons Commons for all the dry contact inputs I Header Mounted Safety Header Mounted Safety Swing side safety sensor not active during door motion typically used with end of rail beams J...

Page 8: ...act 2 Program 1 with Auto reverse in closing the door will power open slowly if blocked or pushed open during closing 3 Program 1 with Safety Stop 4 Reserved 5 Alternate action activate to open activate to close DANGER This controller must be adjusted to ANSI standards by a qualified person Refer to the latest version of ANSI BHMA A156 10 and A156 19 for proper door setup Ensure the door is setup ...

Page 9: ...rol before proceeding To enable the High Energy Programs the control box must be opened and jumper J2 must be moved to the High Energy position Safety sensors that are configured to meet the latest ANSI BHMA A156 10 and A156 19 standards are required for High Energy operation High Energy Low Energy DANGER When using High Energy Programs appropriate safety equipment must be in place See ANSI standa...

Page 10: ...0 1 2 3 4 6 5 A 9 8 7 F E D CB Table Program Selector High Energy Program Description A High Energy applications with safety equipment that meets the latest ANSI BHMA standards B Program A with Auto reverse in closing C Reserved D Alternate action activate to open activate to close DANGER This controller must be adjusted to ANSI standards by a qualified person Refer to the latest version of ANSI B...

Page 11: ...ally pushed Not available for program 5 Alternate Action 2 Sec SWITCHES on off Electric Lock Delay Push Go or Safety Stop Power Boost Continuous 5 Seconds 1 2 3 4 4 High Energy Safety Stop The door will stop while opening if a safety signal is detected through terminals 18 19 or N O normally the doors will slow Slow speed opening resumes after 2 seconds Note If the Hold Open voltage is set too hig...

Page 12: ...Normally open Electric Lock Relay V Secondary Activate Zone W common 2 3 Position Switch T Breakaway U common Breakaway switch Jumper if no breakaway switch Y common Z X 2 3 Position Switch Z Electric Lock Depending on Lock requirement Motion Access 3 Position Switches Rocker MA40011 or Key Switch MA40111 Off Auto Hold Open green red black Secondary Activation Sensor 120 VAC LINE into header Neutr...