Motic SILVER3H Series Instruction Manual Download Page 13

COMMON PROBLEMS IN MICROSCOPY

CA

UTION

CA
UTION

NEVER DISASSEMBLE MECHANICAL OR OPTICAL COMPONENTS. THIS SERVICING SHOULD ONLY BE DONE BY AN 

AUTHORIZED MOTIC TECHNICIAN. THE WARRANTY WILL BE NULL AND VOID IF THE MECHANICAL OR OPTICAL COM-

PONENTS ARE DISASSEMBLED BY A NON-MOTIC DEALER.

SILVERLINE WARRANTY

Motic assures that the microscope in respect of mechanical and optical parts is guaranteed against defects in material and workmanship 

for ten years. Electrical and electronical components are covered for two years after purchase. Normal wear, routine maintenance, light 

bulbs, power supplies, rechargers, batteries, fuses, cords, add-on accessories, damage resulting from repair by unauthorized parties, 

accident, alteration, shipping, misuse or abuse is not covered. Warranty service is provided by Motic authorized technicians. Determination 

of warranty is at the technician’s discretion.

Other than set forth above, Motic hereby disclaims all warranties, expressed or implied, of fitness for a particular purpose.

Defective products covered by the warranty will be repaired free of charge when they are returned to:

Motic Europe, S.L.U.

Pol. Ind. Les Corts · C. Les Corts, 12 · 08349 Cabrera de Mar · Barcelona · Spain

T. +34 93 756 62 86  |  F. +34 93 756 62 87  |  [email protected]

SILVER

3H

 

SERIES

 

|  13 

  

SILVER

 LINE

SILVER

 LINE

Summary of Contents for SILVER3H Series

Page 1: ...SILVER3H SERIES INSTRUCTION MANUAL ENGLISH SILVER LINE...

Page 2: ...can be dismounted either to attach it on a standard camera tripod or to take it with you on a field trip It is cordless using energy efficient rechargeable LED illumination made of metal and compact s...

Page 3: ...ger outer knob of the focus control which facilitates rapid and heavy movement of the focusing mechanism In order to prevent gear damage the focus control is equipped with an upper limit stop that pro...

Page 4: ...or both transmitted bottom and incident top light the illumination system may be used while the SILVER3H is charging IRIS DIAPHRAGM The iris diaphragm is a round device that is mounted below the stage...

Page 5: ...X SIEDENTOPF SILVER3H B only A binocular head design where the interpupillary adjustment increasing or decreasing the distance between the eyepieces is achieved by pivoting the eyepiece tubes in an up...

Page 6: ...stinct image above and below the focal plane Depth of focus decreases with the increase of numerical aperture or with the increase of magnification EYE POINT OR EYE RELIEF The distance from the eyepie...

Page 7: ...The ability of a lens to define the details of the specimen at a maximum magnification This is governed by the N A Numerical Aperture of the lens For example a 40X objective with a N A of 0 65 has a...

Page 8: ...roscopic stage with a built in 0 65 N A condenser iris diaphragm stage clips and swing out white filter STAGE POSITION ADJUSTMENT Proper stage height is critical for achieving the correct focusing dis...

Page 9: ...on the stage securing it with the stage clips Center the specimen in the optical path 6 After securing and moving the slide into position rotate the nosepiece to place the lowest power 4X objective in...

Page 10: ...he same as for the 40X objective since the angle of the required light is determined by the numerical aperture N A of the objective The proper aperture of the diaphragm can be easily achieved after mi...

Page 11: ...into focus The specimen may require some centering in the field of view at this time By using the fine focusing knob slowly and carefully refine the focus to clearly observe the fine details of the sp...

Page 12: ...he eyepiece to moisten the lens and wiping dry with a clean lens tissue is sufficient to clean the surface Lenses should never be wiped while dry as this will scratch or otherwise mar the surface of t...

Page 13: ...outine maintenance light bulbs power supplies rechargers batteries fuses cords add on accessories damage resulting from repair by unauthorized parties accident alteration shipping misuse or abuse is n...

Page 14: ...882 2792 Motic Europe S L U Spain Pol gon Industrial Les Corts C Les Corts 12 08349 Cabrera de Mar Barcelona Spain Tel 34 93 756 6286 Fax 34 93 756 6287 CCIS is a trademark of Motic Incorporation Ltd...