13
Step 4: Measure the DC current from +out terminals (+ and COM1) with the DMM and keyin the
value (i.e. if the DMM shows 0.728A, then keyin 0.728 ) followed by the “ENTER” key. The
following message will then appear on the LCD:
Step 5: Repeat step 4. Keyin the measured value (i.e. if the DMM shows 2.491A then keyin 2.491)
followed by
the “ENTER” key. The following message will then appear on the LCD:
Step 6: Measure the DC voltage from
–output terminals ( - and COM1) with the DMM and keyin the
measured value (i.e. if the DMM shows 9.624V then keyin 9.624) followed by the “ENTER”
key.
The following message will then appear on the
Step 7: Repeat step 6.Keyin the measured value (i.e. if the DMM shows 30.036V, then keyin 30.036)
followed by the “ENTER” key. The following message will then appear on the LCD:
+I Hi=2.491
CV
CV
INDEP
5V
ADC GET=02579
CC
CC
TRACK
3.3V
ADC GET=01039
CV
CV
INDEP
5V
-V Lo=09.624
CC
CC
TRACK
3.3V
ADC GET=03099
CV
CV
INDEP
5V
-V Hi=30.036
CC
CC
TRACK
3.3V