Data_Indicator Pro
User manual
Revision 210224
Page 17
Reference /10 :
basis value for calculating “Opacity” and “Opacity
rel to Alarmlevel” values divided by 10, given in
digits.
Temperature deg. :
sensor temperature in °C with a resolution of 1°C
Oilmist mg/l :
absolute concentration of oil mist in mg/l
Transmission /10 :
amount of light that reaches destination in the
measuring unit of OMD sensor, given in digits
divided by 10. A raw measurement value. Sensor
initially calibrated in a transparent environment
shows transmission about 1000 digits.
Temperature 1/10 deg. :
sensor temperature in °C with a resolution of 0.1°C
Temperature deviation :
deviation of sensor temperature from the average
value of all measured sensors
3.3. COT temperature diagrams (Crankpin Oil Temperature)
Fig. III-25. SiCOMS / OCom COT diagrams
COT temperature diagram
shows sensor temperature values at a selected time
point in °C with a resolution of 0.1°C.
COT temperature difference diagram
displays the temperature deviation of each
sensor at selected time point from the average temperature of all sensors.