background image

 
 
 
 
 
 
 
 
 

Data_Indicator Pro 

 
 

User Manual 

 

 
 
 
 
 
 

Part. No. 2 900 04 00000

 

 

revision  210224  english

 

 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

           

 

                                                           

 

Kurt-Schumacher-Str. 28-30 
66130 Saarbrücken, Deutschland 

 

e-mail: [email protected]  
web: www.motcomgmbh.com

  

Summary of Contents for Data Indicator Pro

Page 1: ...Data_Indicator Pro User Manual Part No 2 900 04 00000 revision 210224 english Kurt Schumacher Str 28 30 66130 Saarbr cken Deutschland e mail info motcomgmbh com web www motcomgmbh com...

Page 2: ...Y graph and options 5 2 2 Detailed display 7 2 3 Speed difference and thermosignal difference diagrams 8 2 4 BeCOMS BCom section menu 9 3 SiCOMS OCom section 14 3 1 XY graph and options 14 3 2 Sensor...

Page 3: ...COMS SiCOMS and OqCOMS system If measured values indicate a dangerous situation for the engine it can be stopped through an alarm system or manually to avoid serious damages At the same time review an...

Page 4: ...n analysis window for BeCOMS BCom logfiles alternatively menu File Start BeCOMS section Start OqCOMS section open a OqCOMS logfile analysis window alternative menu File Start OqCOMS section Start SiCO...

Page 5: ...ions a The graph displays thermo voltage and engine rotation speed data Tsignal alarm Thermo voltage in percents relative to preset alarm level Speed RPM 10 Engine rotation speed in RPM divided by 10...

Page 6: ...mouse button and move the mouse to the right to enlarge and to the left to shrink the graph in X axis direction Or move the mouse upwards to enlarge and downwards to shrink along Y axis Zoom Box enlar...

Page 7: ...will be displayed in detailed display window speed difference diagram and thermosignal difference diagram windows Event log window d Displays event messages and warnings recorded in the BeCOMS BCom da...

Page 8: ...ifference between engine cylinder speed pink bars relative to the cylinder average speed during the nearest full combustion cycle Thermosignal difference diagram Fig III 6 Thermosignal difference diag...

Page 9: ...MS BCom window has four items While loading a logfile the menu is extended and gets a Cancel command to stop loading a file After BeCOMS data file is loaded the Cancel command is removed 2 4 1 File me...

Page 10: ...the current view of the XY graph using standard Windows Print dialog File Snapshot XY graph create a JPG image out of the current XY graph view Type a file name for the JPG image in the standard Windo...

Page 11: ...ns for polar diagram Detailed Display window chapter III 2 1 Scale polardisplay Angle acceleration option gives possibilities for scaling the angle acceleration signal Scale polardisplay Thermosignal...

Page 12: ...is used to adjust the sensitivity of signal localisation algorithm 2 4 3 Simulation OFF ON menu The menu gives a possibility to scale the logdata values and so simulate different BeCOMS Evaluator sett...

Page 13: ...the time of log file recording Fig III 15 Parameters screen 2 4 5 Polardiagram menu Fig III 16 Polardiagram menu Polardiagram menu options allow to display or hide the plot curves of angular signal t...

Page 14: ...displays measured data from the SiCOMS logfile with time along the X axis See III 2 BeCOMS BCom section XY graph for XY graph navigation commands XY graph displayed values Fig III 18 XY graph display...

Page 15: ...ith Zoom Y command Enlarge XY graph button b Pressing the button extends the XY graph window The button caption changes to Reduce XY graph Event log window status messages c Fig III 20 Event log windo...

Page 16: ...measurement values for the corresponding sensor are shown in XY graph otherwise the values are hidden The options for gauges allow to select which value to display at the gauges only the values select...

Page 17: ...nt value Sensor initially calibrated in a transparent environment shows transmission about 1000 digits Temperature 1 10 deg sensor temperature in C with a resolution of 0 1 C Temperature deviation dev...

Page 18: ...he current logfile Only enabled during file loading Unload logfile unload the current logfile from the application memory Swap Month Day changes appearance of day and month in the date label at XY gra...

Page 19: ...Data_Indicator Pro User manual Revision 210224 Page 19 3 4 2 Parameter menu opens a window with Evaluator parameters recorded in the logfile Fig III 27 SiCOMS OCom Parameter window...

Page 20: ...window 4 1 XY graph and options a The XY graph displays OqCOMS monitoring data as time graphs Its navigation commands are identical to those in chapter III 2 BeCOMS BCom section XY graph XY graph dis...

Page 21: ...of oil degradation it grows as the oil ages Clean oil has a Loss Factor Percentage around 0 the oil that s worn out between 25 and 30 Values less 0 can indicate that no oil is detected sensor is surr...

Page 22: ...raph window The button caption changes to Reduce XY graph Event log window status messages c Fig III 31 Event log window The window displays event messages and warnings produced by the OqCOMS system d...

Page 23: ...they are hidden Fig III 33 Gauge for sensor Nr 2 For oil quality measurement values gauge scale is divided into colour regions to indicate oil condition green for usability region yellow for warning...

Page 24: ...us TCP Server window Pressing the BeCOMS data button opens the BeCOMS Modbus TCP data window where the received information is formatted into BeCOMS records and visualised in a way similar to BCom Dat...

Page 25: ...Com Data Logger there is a menu allowing to select which values to show in the XY Chart Fig III 40 BeCOMS Modbus TCP data window XY Chart menu Setup menu opens a window for configuring the number of B...