Descaling and Sanitizing
GENERAL
You are responsible for maintaining the ice machine in accordance with the instructions in
this manual. Maintenance procedures are not covered by the warranty.
Descale and sanitize the ice machine every six months for efficient operation. If the ice
machine requires more frequent descaling and sanitizing, consult a qualified service
company to test the water quality and recommend appropriate water treatment. An
extremely dirty ice machine must be taken apart for descaling and sanitizing.
Manitowoc Ice Machine Descaler and Sanitizer are recommended for use in this ice
machine.
,
Caution
Manitowoc Ice Machine Descaler and Sanitizer can be used for this application
(Manitowoc Descaler part number 9405463 and Manitowoc Sanitizer part number
9405653). It is a violation of Federal law to use these solutions in a manner inconsistent
with their labeling. Read and understand all labels printed on bottles before use.
,
Caution
Do not mix Descaler and Sanitizer solutions together. It is a violation of Federal law to
use these solutions in a manner inconsistent with their labeling.
n
Warning
Wear rubber gloves and safety goggles (and/or face shield) when handling Ice Machine
Descaler or Sanitizer.
DETAILED DESCALING AND SANITIZING PROCEDURE
This procedure must be performed a minimum of once every six months.
• The ice machine and bin must be disassembled, descaled and sanitized.
• All ice produced during the procedures must be discarded.
• Removes mineral deposits from areas or surfaces that are in direct contact with water.
Section 3
Cleaning and Sanitation
Summary of Contents for PKM0335
Page 2: ......
Page 6: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 10: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 54: ...CETTE PAGE LAISSÉE EN BLANC INTENTIONNELLEMENT ...
Page 98: ...SE HA DEJADO ESTA PÁGINA EN BLANCO INTENCIONALMENTE ...
Page 135: ......