Mosquito 12G-1202 Owner'S Manual Download Page 5

12 Gallon Extractor

12 Gallon Extractor

5

4

17. The voltage and frequency indicated on the name plate must 

      correspond to the wall receptacle supply voltage.

18. When cleaning and servicing the machine, local or national regulations

      may apply to the safe disposal of liquids which may contain: chemicals,

      grease, oil, acid, alkaline, or other dangerous liquids.

Preparation

1. Remove furniture and other items from the area you are going to clean.

2. Vacuum carpet and upholstery, and remove debris.

3. Protect cabinets, walls and painted surfaces with drop cloths or plastic.

4. Inspect power cords for damage.

Operating Instructions

1.   Fill the solution tank.

2.   Attach female end of a solution hose to a wand or other tool and the

      male end to the Extractor’s Quick Disconnect (QD).

3.   Plug in power cords: Extractor Model: Using two separate   

      circuits/breakers, plug in the grounded power cables as previously     

      instructed using the appropriate grounding techniques. The green

      indicator to the right of the PSI gauge will illuminate and sound a tone  

      when plugged into separate circuits/breakers.

i.    Activate the switches using the following steps:

ii.   When the hoses are attached, turn Pump-Out Switch.

iii.  (500psi only)The Prime Valve and Pressure Regulator are located on    

      the front right side of the solution tank and should be primed prior to  

      use. To prime the pump turn the valve to the Prime position for 30     

      seconds, and then turn horizontally to the Run position.

iiii.  Pull your wand’s trigger to ensure water is running through the lines 

      to avoid damage to the Pump and Heating unit (Extractor).

5.   If the heater is to be used, prime the system first. Turn on the heater 

      switch and allow it to heat up for 5 minutes

6.   To clean, make two dry passes for every one wet pass while working

   away from the power cords. For optimal use or heavily soiled areas,

   repeat wash steps in the opposite direction.

7.   To prevent motor or internal damage, use a  foam control solution in 

      the recovery tank. Remember to check for build-up in both the recovery  

      and solution tanks!

8.   Empty the Recovery Tank when the internal shut off disengages the

   vacuum. Attach the 45º drain elbow to the drain spout located in the  

   back and lift the dump valve to empty the tank.

9.   Squeeze the wand or tool’s trigger for five seconds after turning the

      power switches off to relieve any existing line pressure.

10. When the machine is off: unplug the power cables, remove solution

 and vacuum hoses, and empty the recovery tank by attaching the 

 45º drain elbow.

11. To empty the solution tank, twist off the solution tank drain cap located   

      on the back of the machine after use

 

1. Before storing the machine, drain, rinse and dry both the tanks 

 

    and vacuum hoses of any residual water or solution.

 

2. Store standing upright in a dry, enclosed location.

 

3. Leave the recovery tank lid open for better air circulation.

 

4. If storing in freezing temperatures, take extra precautions to 

 

    make sure the machine and solution systems are completely 

 

    drained and dry.

Summary of Contents for 12G-1202

Page 1: ...ly possible it s true No extractor design has ever incorporated so many advanced features and patented innovations in a single design We urges you to compare the 12 Gallon side by side to any competit...

Page 2: ...ical shock or Injury Preparation Operating Instructions Maintenance Schedule Filter Maintenance Vacuum Stack filters Pump filters In line Filter Trouble shooting Pump does not work properly Extractor...

Page 3: ...OT Pour liquid into front cavity For best results use 100 water Do not use more chemical than directed Over use of chemical clogs jets brass and reducing heater performance Stores into slot below dump...

Page 4: ...es and replace if necessary The Green or Green Yellow wire in the cord is the grounding wire When replacing a plug this wire must be attached to only the grounding pin Parts and Service Please contact...

Page 5: ...then turn horizontally to the Run position iiii Pull your wand s trigger to ensure water is running through the lines to avoid damage to the Pump and Heating unit Extractor 5 If the heater is to be u...

Page 6: ...ing and install housing back into base by rotating it Trouble Shooting There is no power 1 Plug power cord s in proper outlet s 2 If using two cords make sure each is plugged into a separate circuit 3...

Page 7: ...r 50 long 30 150 0013 3 4 Hose Clamp 31 500 0031 Inline Strainer for Extractor 32 201 0021 1 2 Inlet Hose from Strainer to 500 psi Pump 6 long 33 300 0003 1 4 Inline Check Valve 34 300 0009 1 4 Female...

Page 8: ...acket for Extractor Tanks 79 400 0026 Tank Wall Horizontally Mounted Float Switch 80 800 0033 Trim for Extractor Control Panel 81 100 0051 6 32 Hex Nut Steel Zinc Plated 82 400 0031 LED Indicator Red...

Page 9: ...aight Brass 120 300 0037 1 4 Branch Tee 121 300 0005 1 4 Hose Barb x 1 4 MNPT 90 Degree Brass 122 150 0012 Oetiker Clamp 140 123 201 0022 1 4 Clear Braided Hose from Bypass Regulator to Solution Tank...

Page 10: ...12 Gallon Extractor 10 ELECTRICAL WIRING DIAGRAM...

Page 11: ...12 Gallon Extractor 11...

Page 12: ......

Reviews: