21/01/19 CJ5CA051_EN
ENGLISH
ENGLISH
GENERATOR
GE 35 PS SX
GE 35 PS SX (vers. 350 l)
Stand-by three-phase power
33 kVA (26.4 kW) / 400 V / 47.6 A
PRP three-phase power
30 kVA (24 kW) / 400 V / 43.3 A
PRP single-phase power
11 kVA / 230 V / 47.6 A
COP power
/
Frequency
50 Hz
Cos
ϕ
0.8
ALTERNATOR
self-excited, self-regulated, brushless
Type
synchronous, three-phase
Insulation class
H
ENGINE
Make / Model
PERKINS / 1103A - 33G
Type / Cooling system
Diesel 4-Stroke / Water
Cylinder / Displacement
3 / 3.3 l
Stand by net power
30.4 kW (41.3 HP)
PRP net power
27.3 kW (37.7 HP)
COP net power
/
Speed
1500 rpm
Fuel consumption (75% of PRP)
5.4 l/h
Cooling system capacity
10.2 lt
Engine oil capacity
7.8 l
Starter
Electric
GENERAL SPECIFICATIONS
Battery
12V - 80 Ah
Tank capacity
100 l
350 l
Running time (75% of PRP)
18.5 h
65 h
Protection
IP 44
IP 44
*Dimensions / max. on base Lxwxh
2050x900x1420
2050x900x1730
*Weight on base
960 Kg
1150 Kg
Measured acoustic power LwA (pressure LpA)
88 dB(A) (63 dB(A) @ 7 m)
Garanteed acoustic power LwA (pressure LpA
89 dB(A) (64 dB(A) @ 7 m)
* Dimensions and weight without trolley/trailer
2000 / 14 / CE
M
1.5
TECHNICAL DATA
GE 35 PS SX
REV
.0-01/19
OUTPUT
Output powers according to ISO 8528-1 (temperature 40°C, 30% relative humidity, altitude 1000 m above sea level).
Stand-by power (LTP):
emergency power. Maximum power available for use with variable loads for a number of hours/year limited to 500 h. Overloads are
not permitted.
PRP power
: continuous power with variable loads. Maximum power available for use with variable loads for an unlimited number of hours/year. The average
power output during a 24 h period must not exceed 70% of the stated value.
COP power
: continuous power with constant load. Maximum power available for use with constant load for an unlimited number of hours/year.
A 10% overload is permitted one out of every 12 hours.
On average, it reduces by 1% every 1000 m above sea level and by 3% for every 5°C above 40°C.
ACOUSTIC POWER LEVEL
ATTENTION
:
The concrete risk due to the machine depends on the conditions in which it is used. Therefore, it is up to the end-user and under his direct
responsibility to make a correct evaluation of the same risk and to adopt specific precautions (for instance, adopting a I.P.D. -Individual Protection Device)
Acoustic Noise Level (LWA) - Measure Unit dB(A)
: it stands for acoustic noise released in a certain delay of time. This is not submitted to the distance
of measurement.
Acoustic Pressure (Lp) - Measure Unit dB(A)
: it measures the pressure originated by sound waves emission. Its value changes in proportion to the
distance of measurement.
The here below table shows examples of acoustic pressure (Lp) at different distances from a machine with Acoustic Noise Level (L
WA
) of 95 dB(A)
Lp a 1 meter = 95 dB(A) - 8 dB(A) = 87 dB(A)
Lp a 7 meters = 95 dB(A) - 25 dB(A) = 70 dB(A)
Lp a 4 meters = 95 dB(A) - 20 dB(A) = 75 dB(A)
Lp a 10 meters = 95 dB(A) - 28 dB(A) = 67 dB(A)
NOTE
:
the symbol
2000 / 14 / CE
when with acoustic noise values, indicates that the device respects noise emission limits according to 2000/14/CE directive.
40