The generating set GE 22 is a unit which transforms the mechanical energy, generated by endothermic engine, into electric
energy, through an alternator.
Is meant for industrial and professional use, powered by an endothermic engine; it is composed of various main parts such as:
engine, alternator, electric and electronic controls, the fairing or a protective structure.
The assembling is made on a steel structure, on which are provided elastic support which must damp the vibrations and also
eliminate sounds which would produce noise.
Technical data
GE 22 VSX
GENERATOR
Power three-phase (Stand-by)
20 kVA (16 kW) / 400 V / 28.9 A
Power three-phase (PR.P.)
18 kVA (14.4 kW) / 400 V / 26 A
Power single-phase
7 kVA / 230 V / 30.4 A
Frequency
50 Hz
Cos
ϕϕϕϕϕ
0.8
ALTERNATOR
Self-excited, self-regulated, brushless
Type
three-phase, synchronous
Insulation class
H
ENGINE
Make / Model
VM-MOTORI / SUN 2105E2
Type / Cooling system
Diesel 4-Stroke / air
Cylinders / Displacement
2 / 1992 cm
3
Power (Stand-by)
18.5 kW (25 HP)
Power (PR.P.)
17 kW (23.1 HP)
Speed
1500 rpm
Fuel consumption (75% of PR.P.)
4 l/h
Engine oil capacity
5.5 l
Starter
electric
GENERAL SPECIFICATIONS
Battery
12V - 100Ah
Tank capacity
60 l
Running time (75% of PR.P.)
15 h
Protection
IP 23
Dimensions Lxwxh (mm) *
1720x980x1080
Weight *
703 Kg
Measured acoustic power LwA (pressure LpA)
93 dB(A) (68 dB(A) @ 7 m)
Guaranteed acoustic power LwA (pressure LpA)
94 dB(A) (69 dB(A) @ 7 m)
* Dimensions and weight are inclusive of all parts.
© MOSA
REV.0-04/10
GE 22 VSX
M
1.5
Technical data
12/04/10 34240-GB
2000 / 14 / CE
OUTPUT
Declared power according to ISO 8528-1 (temperature 25°C, 30% relative humidity, altitude 100 m above sea level).
(*Stand-by) = maximum available power for use at variable loads for a yearly number of hours limited at 500 h. No overload is
admitted.
(**Prime power P.R.P.) = maximum available power for use at variable loads for a yearly illimited number of hours. The average
power to be taken during a period of 24 h must not be over 80% of the P.R.P.
It’s admitted overload of 10% each hour every 12 h.
In an
approximative
way one reduces: of 1% every 100 m altitude and of 2.5% for every 5°C above 25°C.
ACOUSTIC POWER LEVEL
ATTENTION:
The concrete risk due to the machine depends on the conditions in which it is used. Therefore, it is up to the end-
user and under his direct responsibility to make a correct evaluation of the same risk and to adopt specific precautions (for
instance, adopting a I.P.D. -Individual Protection Device)
Acoustic Noise Level
(L
WA
)
- Measure Unit dB(A):
it stands for acoustic noise released in a certain delay of time. This is not
submitted to the distance of measurement.
Acoustic Pressure (Lp)
- Measure Unit dB(A):
it measures the pressure originated by sound waves emission. Its value
changes in proportion to the distance of measurement.
The here below table shows examples of acoustic pressure (Lp) at different distances from a machine with Acoustic Noise
Level
(
L
WA
)
of 95 dB(A)
Lp a 1 meter = 95 dB(A) - 8 dB(A) = 87 dB(A)
Lp a 7 meters = 95 dB(A) - 25 dB(A) = 70 dB(A)
Lp a 4 meters = 95 dB(A) - 20 dB(A) = 75 dB(A)
Lp a 10 meters = 95 dB(A) - 28 dB(A) = 67 dB(A)
PLEASE NOTE:
the symbol when with acoustic noise values, indicates that the device respects noise emission limits
according to 2000/14/CE directive.
2000 / 14 / CE