5
DK ENG
The chimney and the flue pipe must be fitted with cleaning doors, which must be at least the
same size as the chimney’s aperture area.
The chimney must be accessible for external inspection, and it must be possible to access the
cleaning doors and the chimney if it is to be cleaned from the top (e.g. steel chimneys).
1.6 Connecting the flue pipe
The flue collar can be rotated and be used for ø150 (inside and outside the flue collar) and
ø120 connections.
Mounting the flue collar pointing upwards
From the factory, the stove is prepared for installation with the flue collar provided (1) pointing
upwards. The ball stop, which prevents the chimney sweep from damaging the stove’s baffle
plates while sweeping, is the 128 mm long rod that is provided in the stove. The flue collar stop
bar is fitted when installing the chimney.
Mounting the flue collar to the rear
Lift the top panel and convection back panel from the stove.
Remove the smoke outlet from the top outlet. The smoke
outlet must not be used when connecting the flue
pipe to the rear.
Remove the round plate which is fixed with 2 screws
at the rear of the stove and fix it instead on the top
outlet.
With a hammer use light, firm taps to knock out the
iron piece on the convection back panel from the
small “bridges” holding the piece in place.
When connecting the flue pipe to the rear, use the
other cast smoke outlet supplied with 40 mm inser-
tion depth.
The ball stop must not be used when installing the
flue collar to the rear.
Lift the top panel and convection back panel back into
place.
A round section is provided which can be placed in the
top panel and cover for the blocked off smoke outlet.
The location of the baffles
The baffles (2) and (3), which are made from vermicu-
lite, are mounted on delivery.
Make sure that the baffles are correctly assembled
before lighting the stove (please see the sketch).
Fresh air connection, if required
Downwards:
The stove is fitted ex works with a branch piece under the stove for fresh air connection, if re-
quired.
Rearwards:
Lift the top plate and convection back panel off the stove and remove the branch piece under
the stove. Remove the round plate fitted with two screws at the bottom at the back of the stove
and, instead, attach it where the branch piece was previously fitted under the stove. Re-fit the
branch pipe where the round plate was previously fitted at the back of the stove. The iron pie-
ce at the bottom of the convection back panel is knocked out with light, firm taps with a ham-
mer next to the small ”bridges” holding the piece in place. Lift the convection back panel and
top plate back into place.