MORSø UK
UNIT 7 THE IO CENTRE, VALLEY DRIVE
RUGBY, WARWICKSHIRE CV21 1TW
WWW.MORSO.CO.UK
MORSO.CO.Uk/PRODUCT/MORSO-Db15
Morso DB15 Central Heating Stovewith DTRG Downburn Firebox
Fuel
Anthracite
Biomass
(Beech
Logs)
Biomass
(Joinery
Waste)
Lignite
Bituminous
Coal
Test Standard
EN 13240:2001 +A2:2004
Flue Draught Pa (ins WG)
12
12
12
12
12
Efficiency %
80.7%
80.0%
78.2%
79.5%
80.7%
Recommended Rating to
room kW
5.8
5.7
6.2
7.8
9.1
To water, kW
6.3
8.8
7.9
7.7
7.6
Total Output, kW
12.1
14.5
4.1
15.5
16.7
Mean Flue Gas Temp Rise ºC
200 °C
263 °C
251 °C
276 °C
241 °C
CO % @ 13% o
2
0.06%
0.24%
0.07%
0.24%
0.23%
Minimum room air entry
requirement
8000 mm²
Minimum Clearance to
combustibles
100mm at sides and back
Temperature underneath can exceed 100°C - traditional hearth required
These stoves exceed the safety and performance requirements of European Standards
Intermittent burning solid fuel roomheaters for installation with a single dedicated chimney.
Independently tested by SGS Nederland BV. Notified Body 0608 - May 2011
CD7454