6
Installation of wall-hung
Morsø 7370/7470
The wall mounting is supplied with 8 holes for fix-
ing to the wall with expanding bolts. A minimum
of 4 of the 8 holes in the wall mounting must be
used to fix the oven to the wall.
The bolts must be sized to ensure that the wall and
the material it is made of are capable of support-
ing the oven. The self weight of the oven is 114 kg.
The installer/ client must therefore ensure that the
wall/ chimney can support the oven in an appropri-
ate manner. Note that unit chimneys and unlined ½
brick chimneys do not always have the necessary
load-bearing capacity. If you are in any doubt, you
should therefore contact a qualified person.
The wall mounting may be used as a drilling tem-
plate. The minimum clearance to a flammable floor
is 275 mm.
Note that plastic wall plugs must not be used be-
cause of the effects of heat.
A wall bushing must be built in correctly to the wall
if a rear smoke outlet is wanted (see sketch) and the
wall mounting must be fitted to the wall.
After unpacking the basic oven, remove
the loose parts of the oven. The ash
drawer, the lower smoke baffle made of
vermiculite, the cast grate and the inter-
mediate base should be removed.
The heat screen on the rear of the oven
must be screwed off and must not be
used with the wall-hung version.