background image

morsedrum.com

Copyright 2022  -  Morse Mfg. Co., Inc. 

 

Form OM515-115 (249855-______) 

(Updated 23 Feb, 2022) 

5

The Specialist In Drum Handling Equipment

Model 515-N-115

Vertical-Lift Drum Pourer, Scale-Equipped,  

60”, DC Power Lift and Tilt

Operator’s Manual for Morse Model 515-N-115

with Serial Number 249855 to ______

Operating Instructions

1.  Push the Vertical-Lift Drum Pourer to the drum. 

2.  Using “LIFT” control as described in “Machine Description - 

Controls”, position drum holder assembly with back band at 

middle of drum.  With ratchet plate swung open and cinch 

chain hanging from chain hook, push unit until back band rests 

firmly against drum.  Some adjustment to tilt angle of saddle 

may be necessary to ensure band fits flush on drum.  Engage 

floor lock.

 

3.  Attaching drum:

 Drape cinch chain across front of drum and 

engage chain link into slot in ratchet (Figure 3.2).  Turn ratchet 

clockwise to tighten cinch chain.  If ratchet turns until pawl is 

beyond last ratchet tooth, turn ratchet back and slide next link 

into ratchet slot and try tightening again.  Cinch chain must 

be held tightly against drum with pawl engaged securely in 

ratchet teeth. 

4. 

Operate lift function to lift drum clear of floor.  Disengage floor 

lock.  Roll to dispensing location.  NOTE: Do not allow drum to 

impact on floor, pouring station, etc. or spill or damage could 

occur. 

 

  

 

CAUTION 

– Do NOT transport with drum raised.

  

 

 

 

ALWAYS LOWER THE DRUM HOLDER TO LOWEST POSITION BEFORE TRANSPORTING.   

 

 

 

Unit can become unstable when transporting with raised load. 

5.  Lift drum to desired pouring height.  Operate tilt control as described in “Machine Description - Controls” to adjust drum attitude.  

Floor lock should be engaged while dispensing / draining. 

6. 

When dispensing is complete, tilt drum back to upright position.  Disengage floor lock and lower drum to transporting height; about 6” 

(15 cm) off the floor.

 

 

  

 

WARNING 

- Stay clear of raised drum

 

 

 

 

NEVER allow anyone to be below any part of raised drum handler or drum.  Remain behind push handle    

 

 

 

while handling drum. 

 

  

 

WARNING 

– Do NOT disengage cinch chain when drum is off the ground.

 

 

 

 

When drum is in upright position, lower drum to the floor before releasing cinch chain.

 

7. 

Push unit to drum storage area and lower drum to the floor in upright position.  Release cinch chain from ratchet by applying 

pressure to ratchet handle in clockwise direction with one hand and opening pawl to free ratchet with other hand.  Remove cinch 

chain link from the ratchet.

Figure 3.2

START-UP Procedure

Machine is shipped with hydraulic fluid. 

1.  Install provided hydraulic control levers (threaded rods with black ball handles). 

2.  IMPORTANT:

 BEFORE operation, remove the 

RED

 shipping plug from the 

hydraulic reservoir, and replace with the provided 

BLACK

 breather.

Summary of Contents for 515-N-115

Page 1: ...ke a loop to lift by Attach loop to an overhead crane and raise slowly Limited 2 Year Warranty Morse drum handling equipment is guaranteed against defects in workmanship or materials for two years when used properly within its rated capacity Warranty does not cover wear from normal use or damage from accident or abuse Motors and other purchased parts carry the warranties of their manufacturers For...

Page 2: ...the unit Under no circumstances should any modifications be made to the Morse machinery without factory authorization Any modifications may void the warranty This machine was designed to perform a specific job and alterations may result in injury to operator or machine WARNING No loose fitting clothing Wear close fitting clothing and safety equipment appropriate to the job Loose fitting clothing m...

Page 3: ...er drum insert the correct size Diameter Adapter into the standard drum holder See Diameter Adapter info at https morsedrum com products diameter adapters ONLY Diameter Adapters for drum with 17 5 44 5 cm diameter or smaller have integrated brackets to prevent drum slipping length ways NOTE For 30 gallon 114 Liter PLASTIC drum insert Diameter Adapter AND install Bracket or Top Rim Clamp to prevent...

Page 4: ...Operator should remain behind the push handle during the lift operation Floor Lock Floor lock handle is located on left side of push handle Pulling floor lock handle toward operator until it locks in down position activates the floor lock When floor lock is activated it prevents unwanted free wheeling of unit Floor conditions determine effectiveness of floor lock Operator should verify its holding...

Page 5: ...m to impact on floor pouring station etc or spill or damage could occur CAUTION Do NOT transport with drum raised ALWAYS LOWER THE DRUM HOLDER TO LOWEST POSITION BEFORE TRANSPORTING Unit can become unstable when transporting with raised load 5 Lift drum to desired pouring height Operate tilt control as described in Machine Description Controls to adjust drum attitude Floor lock should be engaged w...

Page 6: ...djust or replace parts as necessary to prevent failure and maintain proper function 3 Inspect the hydraulic system for oil drips hose damage or other signs of wear Inspect the level of the hydraulic fluid Replace any parts that show signs of wear 4 Grease wheel bearings periodically Oil or grease all moving parts including the gears and sprockets in the tilt drive and the ratchet and pawl 5 Worn o...