background image

The Specialist In Drum Handling Equipment

Model 400AM-96-124

Hydra-Lift, 96”, with Spark Resistant Parts, 

Air Power Lift, Manual Tilt

Operator’s Manual for Morse Hydra-Lift Karrier Model 400AM-96-124

with Serial Number 1210 to ____ (MMYY)

morsedrum.com

Copyright 2022 - Morse Mfg. Co., Inc. 

 

Form OM400AM-96-124 (1210-____)  

(Updated 3 Mar., 2022)

 

5

CAUTION

 

– Do Not Transport with Drum Raised

ALWAYS LOWER THE DRUM HOLDER TO LOWEST POSITION BEFORE TRANSPORTING. 

 The 

unit can become unstable when transporting with a raised load.

5.) Lift drum to desired pouring height.  Operate the tilt control as described in 

“Machine Description - Controls”

 to adjust 

the drum attitude.  This is especially important when lifting an open drum.  The floor lock should be engaged while 

dispensing / draining.

6.) When dispensing is complete, tilt drum back to upright position.  Disengage the floor lock and lower the drum to 

transporting height; about 6” (15 cm) off the floor.

WARNING

 - Stay Clear of Raised Drum

NEVER allow anyone to be below any part of a raised drum handler or drum.  Remain behind 

the push handle while handling a drum.

WARNING

 – Do NOT Disengage the Cinch Chain When Drum is off the Ground

When the drum is in the upright position, lower the drum to the floor before releasing the cinch 

chain.

7.) Push the unit to the drum storage area and lower to the floor in an upright position.  Release the cinch chain from the 

ratchet by applying pressure to the ratchet handle in a clockwise direction with one hand and opening the pawl to free 

the ratchet with the other hand.  Remove the cinch chain link from the ratchet.

Operating Instructions

1.)  

Push Hydra-Lift Karrier to the drum.

2.)  Using “LIFT” control as described in “

Machine Description - 

Controls

”, position drum holder assembly with back band at 

middle of drum (Figure 3.1).  With ratchet plate swung open 

and cinch chain hanging from chain hook, push unit until 

back band rests firmly against drum.  Some adjustment to tilt 

angle of saddle may be necessary to ensure band fits flush on  

drum.

3.) 

Attaching the drum:

Drape the chain across the front of the drum and engage a 

link into the notch in the ratchet (Figure 3.2).  Turn the ratchet 

clockwise to tighten chain.  If ratchet turns until the pawl is 

beyond the last ratchet tooth, turn the ratchet back and slide 

the next link into the ratchet notch and try tightening again.  

The chain must be held tightly against the drum with the pawl 

engaged securely in the ratchet teeth.

4.) Operate lift function to lift drum clear of floor.  Roll to dispensing 

location.  NOTE: Do NOT allow drum to impact on floor, 

pouring station, etc. or a spill or damage could occur.

START-UP Procedure

Machine is shipped with hydraulic fluid. 

1. 

Install provided hydraulic control levers (threaded rods with black ball handles).

 

2.  IMPORTANT:

 BEFORE operation, remove the 

RED

 shipping plug from the hydraulic reservoir, and replace with the 

provided 

BLACK

 breather.

Figure 3.2

Summary of Contents for 400AM-96-124

Page 1: ...ht always sign noting the damage on the BILL OF LADING Document the damage and have the truck driver sign We recommend keeping a digital camera at your receiving dock for this purpose Open packages expeditiously to check the condition of the goods There is only a 24 hour window to notify the carrier of any concealed damage IMMEDIATELY REPORT ALL DAMAGE TO THE SHIPPING COMPANY Then you may contact ...

Page 2: ... Floors Only For operation only on clean level floors of suitable bearing capacity Do not use on sloped surfaces ramps irregular or debris strewn floors WARNING Do Not Modify the Unit Under no circumstances should any modifications be made to the Morse machinery without factory authorization Any modifications may void the warranty This machine was designed to perform a specific job and alterations...

Page 3: ...t drum handler 55 30M Series Spark Resistant Diameter Adapters for drum with diameter smaller than 22 56 cm To handle a smaller drum insert the correct size Diameter Adapter into the standard drum holder See Diameter Adapter info at https morsedrum com products diameter adapters ONLY Diameter Adapters for drum with 17 5 44 5 cm diameter or smaller have integrated brackets to prevent drum slipping ...

Page 4: ...um around it s middle using a cinch chain and ratchet tightening system It automatically adjusts for 22 to 23 5 56 to 59 7 cm diameter drum The MORCINCHTM Drum Holder also accepts accessories to handle a plastic drum fiber drum or a smaller diameter drum Controls The Morse Hydra Lift Karrier is manually propelled and steered The drum lift is powered by an air motor with an on off valve There are t...

Page 5: ...n Release the cinch chain from the ratchet by applying pressure to the ratchet handle in a clockwise direction with one hand and opening the pawl to free the ratchet with the other hand Remove the cinch chain link from the ratchet Operating Instructions 1 Push Hydra Lift Karrier to the drum 2 Using LIFT control as described in Machine Description Controls position drum holder assembly with back ba...

Page 6: ...ure and maintain proper function Inspect the hydraulic system for oil drips hose damage or other signs of wear Inspect the level and condition of the hydraulic fluid Replace any parts that show signs of wear Grease wheel bearings periodically Oil or grease all moving parts including the three clevis pins and the surfaces of the boom which contact the inside of the mast cap the hinge pin the gears ...

Reviews: