Maintenance

Periodic inspection for the general condition of structural and mechanical components is imperative for safe and efficient 

operation.

Periodically inspect all moving parts, framework, and contact areas for signs of wear, fatigue, or loosening.  Tighten, adjust, 

or replace parts as necessary to prevent failure and maintain proper function.

Inspect the hydraulic system for oil drips, hose damage, or other signs of wear.  Inspect the level and condition of the hy

-

draulic fluid.  Replace any parts that show signs of wear.

Grease wheel bearings periodically. Oil or grease all moving parts including: the three clevis pins and the surfaces of the 

boom which contact the inside of the mast cap, the hinge pin, the gears and sprockets in the tilt drive, and the ratchet and 

pawl.

Worn or damaged parts must be properly replaced with the correct, genuine Morse parts.

Hydraulic pump is shipped filled with Noco Premium plus automatic transmission fluid d/m. Material safety data sheet 
(msds) is available online. Change oil yearly, sooner depending on dirty conditions or outdoor use.

 

Replace oil with Mobil 

dte 24 or equivalent for indoor use (Mobil dte 13 for outdoor use).

Summary of Contents for 400A-60-127

Page 1: ...end keeping a digital camera at your receiving dock for this purpose Open packages expeditiously to check the condition of the goods There is only a 24 hour window to notify the carrier of any concealed damage IMMEDIATELY REPORT ALL DAMAGE TO THE SHIPPING COMPANY Then you may contact Morse for assistance with your freight claim Morse Manufacturing will not be held responsible for any damaged freig...

Page 2: ...n only on clean level floors of suitable bearing capacity Do not use on sloped surfaces ramps irregular or debris strewn floors WARNING Do Not Modify the Unit Under no circumstances should any modifications be made to the Morse machinery without factory authorization Any modifications may void the warranty This machine was designed to perform a specific job and alterations may result in injury to ...

Page 3: ...G manual tilt drum handler 55 30 Series Diameter Adapters for drum with diameter smaller than 22 56 cm To handle a smaller drum insert the correct size Diameter Adapter into the standard drum holder See Diameter Adapter info at https morsedrum com products diameter adapters ONLY Diameter Adapters for drum with 17 5 44 5 cm diameter or smaller have integrated brackets to prevent drum slipping lengt...

Page 4: ...drum handler is equipped with the MORStop Tilt Brake there is no need to hold tension on both sides of the chain loop Braking is immediate and self actuating without additional steps by the operator To add the MORStop Tilt Brake to your drum handler order Kit 3900 P to install on existing drum handler Floor Lock The screw down floor lock is located on the base of the tower figure 3 1 Turning the f...

Page 5: ...n an upright position Release the cinch chain from the ratchet by applying pressure to the ratchet handle in a clockwise direction with one hand and opening the pawl to free the ratchet with the other hand Remove the cinch chain link from the ratchet Figure 3 2 WARNING Watch Out for Pinch Points Stay clear of moving parts Operator should remain behind the push handle during the lift operation Oper...

Page 6: ... proper function Inspect the hydraulic system for oil drips hose damage or other signs of wear Inspect the level and condition of the hy draulic fluid Replace any parts that show signs of wear Grease wheel bearings periodically Oil or grease all moving parts including the three clevis pins and the surfaces of the boom which contact the inside of the mast cap the hinge pin the gears and sprockets i...

Reviews: