background image

The Specialist In Drum Handling Equipment

Model 400A-60-127

Hydra-Lift, 60”, AC Power Lift, Manual Tilt

morsedrum.com

Copyright 2022 - Morse Mfg. Co., Inc. 

 

Form OM400A-60-127 (400000-______)  (Updated 23 Sep, 2022)

 

1

CONTENTS

Page

Receiving Procedures. . . . . . . . . . . . . . . . .  1
Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1
Safety Information. . . . . . . . . . . . . . . . . . . . .  1 - 2
Machine Description. . . . . . . . . . . . . . . . . . .  3 - 4
Accessories. . . . . . . . . . . . . . . . . . . .    3
Start-Up Procedure. . . . . . . . . . . . . . . .   4
Operating Instructions. . . . . . . . . . . . . . . . . . .   5
Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . .  6

Safety Information

While Morse Manufacturing Co. drum handling equipment is 

engineered for safety and efficiency, a high degree of responsibility 

must be placed upon the machine operator to follow safe practices, 

based primarily on common sense, upon which true safety 

depends.

Failure to follow the safety precautions in this manual can result in 

personal injury or property damage. Observe the same precautions 

as with similar machinery where carelessness in operating or 

maintenance is hazardous to personnel. Carefully read the safety 

precautions below and throughout this manual.

Receiving Procedures

Every Morse drum handler is inspected prior to shipping. However, 

damage may be incurred during transit.

• Check for visible damage. If you choose to accept damaged 

freight, always sign noting the damage on the 

BILL OF LADING

• Document the damage and have the truck driver sign. We 

recommend keeping a digital camera at your receiving dock for 

this purpose.

• Open packages expeditiously to check the condition of the 

goods. There is only a 24 hour window to notify the carrier of any 

concealed damage.

• 

IMMEDIATELY REPORT ALL DAMAGE TO THE SHIPPING 

COMPANY!

 Then you may contact Morse for assistance with 

your freight claim.

• Morse Manufacturing will not be held responsible for any 

damaged freight that is not signed for as damaged.

Delivery to non-business addresses without a loading dock result 

in additional freight charges. Residential delivery fees, inside 

delivery fees, re-delivery charges, and lift gate services will be 

added by the truck line, and are non-negotiable.

Limited 2 Year Warranty

Morse drum handling equipment is guaranteed against defects in 

workmanship or materials for 

TWO YEARS

 when used properly 

within its rated capacity. Warranty does not cover wear from 

normal use or damage from accident or abuse. Motors and 

other purchased parts carry the warranties of their manufacturers.

For warranty claims, contact your Morse Dealer to obtain a 

return authorization number, and for return freight advice. Return 

freight must be prepaid.

In all instances, liability is limited to the purchase price paid or to 

repairing or replacing the product. Customer assumes liability for 

any modifications, unauthorized repairs or parts substitution.

Operator’s Manual 

for Morse Hydra-Lift Drum Karrier

Model 400A-60-127

Serial Number 400000 to ______ 

Summary of Contents for 400A-60-127

Page 1: ...end keeping a digital camera at your receiving dock for this purpose Open packages expeditiously to check the condition of the goods There is only a 24 hour window to notify the carrier of any concealed damage IMMEDIATELY REPORT ALL DAMAGE TO THE SHIPPING COMPANY Then you may contact Morse for assistance with your freight claim Morse Manufacturing will not be held responsible for any damaged freig...

Page 2: ...n only on clean level floors of suitable bearing capacity Do not use on sloped surfaces ramps irregular or debris strewn floors WARNING Do Not Modify the Unit Under no circumstances should any modifications be made to the Morse machinery without factory authorization Any modifications may void the warranty This machine was designed to perform a specific job and alterations may result in injury to ...

Page 3: ...G manual tilt drum handler 55 30 Series Diameter Adapters for drum with diameter smaller than 22 56 cm To handle a smaller drum insert the correct size Diameter Adapter into the standard drum holder See Diameter Adapter info at https morsedrum com products diameter adapters ONLY Diameter Adapters for drum with 17 5 44 5 cm diameter or smaller have integrated brackets to prevent drum slipping lengt...

Page 4: ...drum handler is equipped with the MORStop Tilt Brake there is no need to hold tension on both sides of the chain loop Braking is immediate and self actuating without additional steps by the operator To add the MORStop Tilt Brake to your drum handler order Kit 3900 P to install on existing drum handler Floor Lock The screw down floor lock is located on the base of the tower figure 3 1 Turning the f...

Page 5: ...n an upright position Release the cinch chain from the ratchet by applying pressure to the ratchet handle in a clockwise direction with one hand and opening the pawl to free the ratchet with the other hand Remove the cinch chain link from the ratchet Figure 3 2 WARNING Watch Out for Pinch Points Stay clear of moving parts Operator should remain behind the push handle during the lift operation Oper...

Page 6: ... proper function Inspect the hydraulic system for oil drips hose damage or other signs of wear Inspect the level and condition of the hy draulic fluid Replace any parts that show signs of wear Grease wheel bearings periodically Oil or grease all moving parts including the three clevis pins and the surfaces of the boom which contact the inside of the mast cap the hinge pin the gears and sprockets i...