Morris MOR-12LDHE-WIFI Instruction Manual Download Page 6

6

The  appliance  shall  be  stored  in  a  room  without  continuous  operation 
sources  (for  example:  open  flames,  an  operating  gas  appliance  or  an 
operating electric heater). 

The  appliance  shall  be  stored  to  prevent  mechanical  damage  from 
occurring. 

Do not piece or burn, even after use. 

Be aware that refrigerants may not contain an odour. 

Pipe-work  shall  be  protected  from  physical  damage  and  shall  not  be 
installed in an unventilated space, if that space is smaller than 4m

²

Compliance with national gas regulations shall be observed. 

Keep any required ventilation openings clear of obstruction. 

The  appliance  shall  be  stored  in  a  well-ventilated  area  where  the  room 
size corresponds to the room area as specified for operation. 

Any  person  who  is  involved  with  working  on  or  breaking  into  a 

refrigerant  circuit  should  hold  a  current  valid  certificate  from  an  industry-
accredited assessment authority, which authorises their competence to handle 
refrigerants  safely  in  accordance  with  an  industry,  recognised  assessment 
specification. 

Servicing shall only be performed as recommended by the equipment 

manufacturer. Maintenance and repair requiring the assistance of other skilled 
personnel shall be carried out under the supervision of the person competent 
in the use of flammable refrigerants. 
If  you  don't  understand  something  or  need  help,  please  contact  the  dealer 
services 

2.

SAFETY PRECAUTIONS ON SERVICING

 

Please follow these warnings when to undertake the following when servicing 

a dehumidifier with R290. 

2.2.1 Checks to the area 

Prior to beginning work on systems containing flammable refrigerants, safety 
checks  are  necessary  to  ensure  that  the  risk  of  ignition  is  minimised.  For 
repair to the refrigerating system, the following precautions shall be complied 
with prior to conducting work on the system. 

Summary of Contents for MOR-12LDHE-WIFI

Page 1: ...R 12LDHE WIFI Please keep this manual for further reference Thank you for selecting our dehumidifier Be sure to read this manual carefully before using it Any questions please contact enquiries ledfir...

Page 2: ...2 CONTENT 1 BEFORE YOU BEGIN 03 2 FOR YOUR SAFETY 05 3 PRODUCT OVERVIEW 10 4 INSTALLATION 12 5 OPERATION 14 6 MAINTENANCE 19 7 TROUBLESHOOTING 20 8 DECOMMISSIONING 21...

Page 3: ...cient energy properties R290 is highly suitable as a coolant for this application Special precautions must be taken into consideration due to the coolant s high flammability 1 2SYMBOLS FROM THE UNIT A...

Page 4: ...n be circulated by the fans If propane gas is present or even suspected do not allow untrained personnel to attempt to find the cause The propane gas used in the unit has no odour The lack of smell do...

Page 5: ...te with wet hands Prevent water from spilling onto the unit Do not immerse or expose the unit to rain moisture or any other liquid Do not leave the unit running unattended Do not tilt or turn over the...

Page 6: ...should hold a current valid certificate from an industry accredited assessment authority which authorises their competence to handle refrigerants safely in accordance with an industry recognised asses...

Page 7: ...re extinguisher adjacent to the charging area 2 2 6 No ignition sources No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or has con...

Page 8: ...efrigerant containing components unless the components are constructed of materials which are inherently resistant to being corroded or are suitably protected against being so corroded 2 2 9 Checks to...

Page 9: ...9 3 PRODUCT OVERVIEW 1 FRONT VIEW Air Outlet Touch Panel 3 Colour Digital Display Front shell Castors...

Page 10: ...rom the air Low power consumption energy efficient Quiet fan has two speed settings Auto Defrost at low temperature Auto shut off auto restart Electronic control Laundry drying function Antibacterial...

Page 11: ...es or other products that products that produce heat In an area where oil or water may be splashed Direct sunlight Mechanical vibration or shock Excessive dust Lack of ventilation such as cabinet or b...

Page 12: ...es on it Operate this unit in an ambient temperature from 5 C to 35 C Do not use in the outdoors This dehumidifier is intended for indoor residential applications only Do not operate in close proximit...

Page 13: ...tank is correctly fitted otherwise the unit will not operate properly The dehumidifier starts up in the mode selected when the unit was last used The dehumidifier starts dehumidifying if the room humi...

Page 14: ...al humidity set humidity 3 the compressor stops working and fan stops working after 30 seconds delay Both fan speed and humidity can be adjusted under auto mode Continuously drying mode The machine co...

Page 15: ...and you can set the humidity The range of target humidity is 30 35 40 45 50 55 60 65 70 75 80 After setting 3 seconds the system confirms the input value and then the machine exits the setting state a...

Page 16: ...rea with a drain or outside Clean the inside of the tank as well as the outside Replace the empty tank back into the unit Press the POWER button to resume operating If the Water Full light does not ex...

Page 17: ...ld freely flow out of the unit Do not submerge the end of hose into water otherwise it can cause Air Lock in the hose To avoid water spillage As the negative pressure of condensate drain pan is large...

Page 18: ...tance of about 5 meters to your router 4 As long as the power is turned on the WIFI indicator flashes slowly After 3 minutes the status will be canceled if there is no network configuration and the in...

Page 19: ...19 TROUBLE SHOOTING of WIFI CONNECTION Picture1 Picture2 Picture3 Picture4...

Page 20: ...acuum cleaner to gently absorb the dust on the surface If the filter is very dirty wash it with water and a soft detergent and dry it thoroughly afterwards Network connection failed Solution Network c...

Page 21: ...FORE CALLING FOR SERVICE Before contacting professional service please review the trouble shooting list that includes common occurrences that are not the result of a defect in workmanship or materials...

Page 22: ...d component damage and mould Unplug the unit and place it in a dry open area for days to dry it out Another way to dry the unit is to set the humidity point more than 5 higher than the ambient humidit...

Page 23: ...t your local government for information regarding the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and...