![Morris MOR-12LDHE-WIFI Instruction Manual Download Page 6](http://html1.mh-extra.com/html/morris/mor-12ldhe-wifi/mor-12ldhe-wifi_instruction-manual_1836019006.webp)
6
●
The appliance shall be stored in a room without continuous operation
sources (for example: open flames, an operating gas appliance or an
operating electric heater).
●
The appliance shall be stored to prevent mechanical damage from
occurring.
●
Do not piece or burn, even after use.
●
Be aware that refrigerants may not contain an odour.
●
Pipe-work shall be protected from physical damage and shall not be
installed in an unventilated space, if that space is smaller than 4m
²
.
●
Compliance with national gas regulations shall be observed.
●
Keep any required ventilation openings clear of obstruction.
●
The appliance shall be stored in a well-ventilated area where the room
size corresponds to the room area as specified for operation.
Any person who is involved with working on or breaking into a
refrigerant circuit should hold a current valid certificate from an industry-
accredited assessment authority, which authorises their competence to handle
refrigerants safely in accordance with an industry, recognised assessment
specification.
Servicing shall only be performed as recommended by the equipment
manufacturer. Maintenance and repair requiring the assistance of other skilled
personnel shall be carried out under the supervision of the person competent
in the use of flammable refrigerants.
If you don't understand something or need help, please contact the dealer
services
2.
SAFETY PRECAUTIONS ON SERVICING
Please follow these warnings when to undertake the following when servicing
a dehumidifier with R290.
2.2.1 Checks to the area
Prior to beginning work on systems containing flammable refrigerants, safety
checks are necessary to ensure that the risk of ignition is minimised. For
repair to the refrigerating system, the following precautions shall be complied
with prior to conducting work on the system.