Morris 59120 Quick Start Manual Download Page 2

1

Position the unit flat against the wall. 

2

Press Stud Finder button and hold in. The LCD will show ‘STUD’ 

3

Slowly slide unit horizontally across the wall, right of left. As you 

begin to approach a stud, the “

”will appear on LCD two side. From 

side to center. 

4

When the all “

” is lit and the beep sound, you have located the edge 

of the stud. Mark this spot. 

5

Continue scanning beyond the marked spot until the sounds go out. 

Slide unit in reverse direction to locate other edge of stud. 

6

Mark this second spot. Between the two spots is the stud position. 

 

Addition (w/o using Mem) 

1.

 

Press “Read” for measurement. 

2.

 

Press “+/=” to enter the addition mode. A “+”icon will appear on 

LCD. 

3.

 

Press and hold “Read” again for second measurement. 

4.

 

Press “+/=” again the sum is shown on the bottom. 

Addition (using

 Mem

): 

1.

 

Press “Mem input” to save the desired measurement for the addition. 

2.

 

Press “Read” for new measurement. 

3.

 

After getting the new measurement, press“+/=” to enter the addition 

mode .A “+”icon will appear on LCD. 

4.

 

Press “MEM Recall” to recall previous measurement for the addition. 

The“MEM” icon will disappear and the stored memory will be 

automatically cleared. 

5.

 

Press“+/=”again, the sum is shown in the bottom. 

Area:  

1.

 

Press

  to enter area mode for calculation of a room area. 

2.

 

“L” will blink showing which measurement you will be taking. Press 

“Read” to take “L” measurement that is displayed on upper portion of 

screen. (Step1) 

3.

 

“W” will blink showing the next measurement to take. Press “Read” 

to take “W” measurement that is displayed on upper portion of screen. 

(Step2) 

4.

 

Than the Area is automatically displayed on the lower portion of the 

screen. 

5.

 

Pressing the “Read” key again will toggle back and forth between the 

“L” and “W” measurements. 

6.

 

To start another Area mode, press

key again. 

7.

 

To leave the Area mode to make a single measurement, press and 

hold the “Read” key for about 2 seconds. 

Addition of areas under area mode: 

1.

 

Press “Mem input” to save the calculated area. 

2.

 

Press

to measure new area (Follow step1&2 under the Area 

section.) 

3.

 

After getting the desired area, press “+/=” to enter the addition mode. 

A “+” icon would appear on LCD. 

4.

 

Press “Mem Recall” to recall the first calculated area for the addition. 

The “MEM” icon will disappear and the stored memory will be 

automatically cleared. 

5.

 

Press “+/=” again, the sum of both areas is shown on bottom. 

Important note: 

1. 

Before press and hold “Read” to leave the leave the area mode, the 
measurement of “L” and “W” must be completed first. 

Volume 

1.

 

Press

to enter volume mode for calculation of a room volume. 

2.

 

“L” will blink showing which measurement you will be taking. Press 

“Read” to take “L” measurement that is displayed in upper portion of 

screen. (Step1) 

3.

 

“W” will blink showing the next measurement to take. Press “Read” 

to take “W” measurement that is displayed on upper portion of screen. 

(Step2.) 

4.

 

“H” will blink showing the next measurement to take. Press “Read” 

to take “H” measurement that displayed on upper portion of screen. 

(Step3) 

5.

 

Then the volume is automatically displayed on the lower portion of 

the screen. 

6.

 

Pressing the “Read” key again will toggle back and forth between the 

“L”, “W” and “H” measurements. 

7.

 

To start another volume mode, press

 key again. 

8.

 

To leave the volume mode to make a single measurement, press and 

hold the “Read” key for about 2 seconds. 

Addition of volumes under volume mode: 

1.

 

Press “Mem input” to save to the calculated volume. 

2.

 

Press 

  to measure new volume (Follow step1 to 3 under the 

volume section). 

3.

 

After getting the calculated volume, press “+/=” to enter the addition 

mode. A “+” icon would appear on LCD. 

4.

 

Press “Mem Recall” to recall the first calculated volume for the 

addition. The “MEM” icon will disappear and the stored memory will 

be automatically cleared. 

5.

 

Press “+/=” again, the sum of both volumes is shown on bottom. 

Important note: 
1. Before press and hold “Read” to leave the volume mode, the 
measurement of “L”, “W” and “H” must be completed first. 
Mem input: 

Inserts a length, Area or volume into memory 

*The “MEM” icon will appear. 

Mem recall: 

Displays the last stored memory. 

This is either length, Area or volume. 

The “MEM” icon will disappear and the stored memory will be 

automatically cleared. 

FT/M: 

Change the measurement unit for length, Area and volume from ft/in. to 

metric. 

Care and handling: 

1.

 

The laser tape is a precision instrument which must be handled with 

care. 

2.

 

Avoid shock, vibrations and extreme heat. 

3.

 

Avoid dust and water, which may obstruct the lens. If needed, use a 

soft cloth or cotton swab and glass cleaner to clean the lens. 

4.

 

Keep the laser tool dry and clean. 

5.

 

Check battery regularly to avoid deterioration. 

6.

 

Remove battery if the laser tool is to be stored for an extended period 

of time. 

 

Reviews: