Model NO:59120 Ultrasonic Distance Measure AND   

Stud Finder 

 

L

H

W

m sq. f t

cu. f t

m

2

m

3

m

MEM

+

Area

 / 

volume

L length

W

=

Width

H

=

HIGH

Memory

Memory

/

computation
result

Low

 

battery

 

indicator

Square

 

Feet

Cubic

 

Feet

Square

 

Meter

Cubic

 

Meter

A

ddition

Current

 

result

 

LCD Display for Stud Finder 
 

 

 

 
 
Technical Specifications 
Recommended use : 

Indoor

 

Measurement range: 

2’ to 50’ (0.6~15 meters)

 

Accuracy:  

 

±0.5%±1 Digit

 

Resolutions:  

 

1’(0.01M)

 

Aperture angle:   

Approx. 5 ±degrees

 

Laser Diode Type:  

Red laser diode 650nm 

Laser Clas

s:   

 

Class IIIa(US version)/Class II(Europe version) 

Power supply:

 

 

9V block battery 

Calculation range: 
Length

 

 

   -9999’11”(9999M) 

Area 

   -999999 

sq 

ft 

(99999M²) 

Volume

 

   -999999 

cu 

ft 

(99999M³) 

Stud finder: 

Detects wood up to 3/4" (18mm) 

Auto calibration stud detection. 

Operation environment: 
Operation temperature: 

32

 to 104

(0

 to 40

Still air and hard target surface for accurate measurement. 

The tool always measures from the base of the tool. 

Important note: 

For long distance measuring (between 40’to 50’/12M to 15M),the 

relative humidity should be above 48

  and target size of at least 10 ft 

by 10 sq ft /3M BY 3M². 

SAFETY INSTRUCTIONS 
DANGER: ASER RADIATION,VOID DIRECT EYE 
EXPOSURE,SERIOUS EYE INJURE CAN RESULT. 

IMPORTANT 

Please read all instructions prior to operating the tools. 

Warnings 

Use of controls or performance of procedures other than those specified 

herein may result in hazardous radiation exposure. The power of the 

emission of the laser beam is less than 1 mW in class II (Europe) and less 

than 5mW in Class IIIa(U.S.) and Class IIIR(Europe),so the following 

warning must be followed to avoid injury: 

DO NOT stare direct at the laser beam. 
DO NOT project the laser beam directly into the eyes of 
others/animals. 
DO NOT setup the tool at eye level or operate the tools on or near a 
reflective surface, as the laser beam could be projected into you eyes 
or the eyes of others. 
POWER SUPPLY 

The tools require one 9 volt battery to operate 

BATTERY INSTALLATION 

1. Open battery door on back of case.   

2. Connect a 9-volt battery to battery clip.   

3. Insert battery into case and replace battery door.   

When battery is low, the low battery icon will be continuously displayed 

on the LCD. 

How to use the ultrasonic distance meter 

1.

 

Point to wall and get measured distance by press ”Read” 

2.

 

For dynamic read, press and hold “Read” key to get measured 

distance displayed while the unit is moving. 

3.

 

Each measurement erases the previous one. 

4.

 

Measured distance is displayed on top of the LCD screen. 

5.

 

Unit automatically turns itself off after 30 seconds of inactivity. 

IMPORTANT NOTE: 

1.

 

Position and point the unit perpendicular to the target. 

The laser pointer will show where the tool is pointing and is only on 

while a reading is being taken. 

2.

 

The target must be a hard regular surface unencumbered by 

objects/obstacles in the measurement field. 

3.

 

For more accurate result, choose a target that is flat and large with 

hard surfaces. 

4.

 

Put a piece of cardboard in front of the target if the measured target is 

small, irregular or soft. 

5.

 

The ultrasonic distance meter cannot measure through glass, but will 

measure TO glass.   

Using the Stud Finder 

 

 

 

 
laser pointer     
                     
2 Low LCD 
 
                               
Memory input 
Memory recall 
            Ft/M       

+ / =

 

 
Ultrasonic sensor 
 
 
 
Read 
 Vo lume 
 Ar ea 
 

+/= 