2.
Twist connector 1800, until it is in place.
(Fig F)
The fit between the connector and the
tubes and/or handle is tight to ensure no
steam leaks. It is recommended to keep
both parts lubricated to facilitate connecting
and disconnecting.
To detach the accessories, press the
release button (10) and pull the items apart.
Please note accessory heads may be hot!
Please be careful not to trap your fingers.
OPERATING YOUR STEAM CLEANER
Connect the unit to the mains and switch
on the boiler heater by pressing the on-off
button (2). The ‘heater on’ light is illuminated.
Steam will be available in approx. 12 minutes.
When the steam is ready for use the
heater on/off light will turn off.
Make sure that the locking mechanism
(13) on the handle has been released.
If you push the lock (13) towards the rear,
the steam switch can not be operated.
Push the lock forward so that the steam
switch is released. (Fig G)
To make steam ready press the ‘steam
on/off’ button (3) and the orange light
will come on. STEAM IS NOW READY TO
BE RELEASED.
To release steam, press the handle
control switch (12). At the start, always
point the steam handle at a cloth until a
steady flow of steam comes out.
During steam release the heater on/off
light (2) will turn on - this is normal and
is not a fault
To stop releasing steam, simply release
the handle control switch (12).
Refilling
When the boiler is empty no steam, or poor
quality steam is emitted.
The boiler needs to be refilled:
Switch off the boiler heater by pressing
the on/off button (2)
If there is pressure in the boiler, the filler
cap (1) will revolve but a safety feature
prevents it from being unscrewed.
Release any steam pressure in the system
using the on/off switch (3) on machine
and handle (12). Switch off the steam
release button (3). The cap can then be
unscrewed.
Unplug the mains cable.
Leave the product with the filler cap off
for 10 minutes before filling.
Refill the boiler using the funnel (Fig A).
Use warm water to reduce heat up time
Caution: Do not pour cold water into a very
hot boiler as steam and hot water may be
blown out of the filling hole and can scald!!!
Screw the cap back on. Start operation
again (SEE OPERATION SECTION ABOVE)
Switching the unit OFF
Switch the unit off by means of switches
(2) and (3).
Remove the hose plug (7) from the unit
by pressing the button, holding down the
socket flap simultaneously.
Remove the plug from the mains socket.
Any remaining water can be left inside
the unit.
To avoid deforming the brushes (16 & 23),
ensure that the brushes are allowed to
cool down before storing.
USE OF ACCESSORIES
Steam handle (8)
To avoid spurting of heavy and moist steam it
is recommended always to attach an accessory
to the steam handle.
Large floor brush (16)
Recommended applications include:
- carpets and rugs
- sealed timber & parquetry
F
5
Summary of Contents for IB70505
Page 8: ...P N S8792670 06 01 ...