D 1006 Issue 8
KAC ALARM COMPANY LIMITED, KAC House, Thornhill Road, Redditch, Worcestershire, England. B98 9ND. www.kac.co.uk
DIP setting
Nominal
2nd Stage
O=Off/1=On
No
Pattern
Frequency
(BSO-BSS)
(BSO-BSS)
(BSO-BSS)
Switching Frequency
Description
Market
Standard
Tone
SW 1,2,3,4,5
High
Medium
Low
0,0,0,0,0
1
Alternating
525/440
4.19 / 8.13
1.58 / 5.52
0.89 / 4.83
2Hz (100ms/400ms)
French Fire Sound AFNOR
France
NFS 32-001
7
1,0,0,0,0
2
Alternating
800/922
5.56 / 9.50
1.58 / 5.52
1.18 / 5.12
1Hz
UK
BS5839 Pt1
8
0,1,0,0,0
3
Alternating
800/922
3.27 / 7.21
1.58 / 5.52
1.15 / 5.08
2Hz
Alternating tone telecoms
UK
BS5839 Pt1, FP1063.1
8
1,1,0,0,0
4
Alternating
2400/2900
5.8 / 9.74
3.67 / 7.61
1.72 / 5.66
3Hz
Alternating High Frequency
10
0,0,1,0,0
5
Alternating
2500/3100
6.01 / 9.95
3.7 / 7.64
1.72 / 5.66
2Hz
Security Alarm
10
1,0,1,0,0
6
Alternating
988/645
3.08 / 7.02
1.49 / 5.43
1.12 / 5.06
2Hz
8
0,1,1,0,0
7
Continuous
630
4.30 / 8.24
1.48 / 5.42
1.02 / 4.96
All clear
Sweden
1
1,1,1,0,0
8
Continuous
922
4.21 / 8.15
1.39 / 5.33
1.12 / 5.06
BS 5839 Pt 1
2
0,0,0,1,0
9
Continuous
1200
4.08 / 8.02
1.71 / 5.65
1.27 / 5.21
2
1,0,0,1,0
10
Continuous
2810
4.9 / 8.84
3.29 / 7.23
1.56 / 5.5
HF Continuous
4
0,1,0,1,0
11
Sweep
150-1000
3.74 / 7.68
1.71 / 5.65
1.36 / 5.3
Rising from 150Hz to 1000Hz in
10 seconds, then 40 seconds at
1000Hz, then falling from
1000Hz to 150Hz in 10
seconds, then 20 seconds at
150Hz, then repeating. Total
period 80 seconds.
“Gasalarm” Tone
22
1,1,0,1,0
12
Intermittent
420
4.59 / 8.53
1.69 / 5.63
0.84 / 4.78
0.625s on, 0.625 sec off
AS2220 alert tone
NZ, Aus
AS2220
13
0,0,1,1,0
13
Sweep
500-1200
4.46 / 8.4
2.22 / 6.16
1.48 / 5.42
0.25 sec off, 3.75 sec on
AS2220 evacuate tone
NZ, Aus
AS2220
12
1,0,1,1,0
14
Intermittent
630
3.31 / 7.25
1.38 / 5.32
0.98 / 4.92
3.33Hz 150ms on, 150ms off
Swedish alarm tone
Sweden
7
0,1,1,1,0
15
Intermittent
922
2.53 / 6.47
1.38 / 5.32
1.12 / 5.06
0.8Hz 0.25s on, 1s off
Intermittent Tone
UK
BS 5839 Pt 1
8
1,1,1,1,0
16
Intermittent
922
2.57 / 6.51
1.39 / 5.33
1.13 / 5.07
0.5Hz 1s on, 1s off
Back up alarm LF & BS5839
Pt 1
UK
BS5839 Pt 1
8
0,0,0,0,1
17
Intermittent
2810
5.4 / 9.34
2.4 / 6.34
1.59 / 5.53
1Hz
Back up alarm HF & BS5839
Pt 1 2nd tone
UK
BS5839 Pt 1
10
1,0,0,0,1
18
Intermittent
922
2.61 / 6.55
1.4 / 5.34
1.11 / 5.05
1Hz 500ms on, 500ms off
LF BS5839 Pt 1
UK
BS5839 Pt 1
8
0,1,0,0,1
19
Intermittent
950
3.03 / 6.97
1.51 / 5.45
1.21 / 5.15
0.22Hz (0.5s on, 0.5s off) rptx3,
1.5s off
Australia
ISO8201
12
1,1,0,0,1
20
Continuous
800
3.29 / 7.23
1.56 / 5.5
1.17 / 5.11
BS 5839 Pt 1
22
0,0,1,0,1
21
Sweep
400-1200
3.85 / 7.79
1.66 / 5.6
1.15 / 5.09
(0.5s on, 0.5s off)*3, 1.5s off
Temporal 3 Evacuation tone
Australia
ISO8201 Temporal 3
12
1,0,1,0,1
22
Sweep
1200 - 500
4.07 / 8.01
2.96 / 6.9
1.4 / 5.34
0.99Hz 1s on, 0.01s off
Evacuate, DIN tone & PFEER
Germany
DIN, PFEER
20
0,1,1,0,1
23
Sweep
2400 - 2850
4.99 / 8.93
3.08 / 7.02
1.72 / 5.66
7Hz
Fast sweep VdS
Germany
VdS
10
1,1,1,0,1
24
Sweep
500 - 1200
4.36 / 8.3
2.04 / 5.98
1.5 / 5.44
(0.5s off, 3.5s on)
Slow whoop evacuate
Netherlands
Netherlands
NEN 2575
8
0,0,0,1,1
25
Sweep
800 - 970
3.06 / 7.0
1.54 / 5.48
1.19 / 5.13
50Hz
LF Buzz BS5839 Pt 1
UK
BS5839 Pt 1
8
1,0,0,1,1
26
Sweep
800 - 970
2.77 / 6.71
1.59 / 5.53
1.21 / 5.15
7Hz
Fast sweep LF BS5839 Pt 1
UK
BS5839 Pt 1
8
0,1,0,1,1
27
Sweep
800 - 970
2.97 / 6.91
1.67 / 5.61
1.25 / 5.19
1Hz
Medium sweep LF, BS5839 Pt
1, VdS
UK, Germany
BS5839 Pt 1 VdS
8
1,1,0,1,1
28
Sweep
2400 – 2850
4.93 / 8.87
3.07 / 7.01
1.76 / 4.7
50Hz
High frequency buzz
10
0,0,1,1,1
29
Sweep
500 – 1000
2.96 / 6.9
1.45 / 5.39
1.08 / 5.02
7Hz
Fast whoop
8
1,0,1,1,1
30
Sweep
500 – 1200 –
500
4.01 / 7.95
1.7 / 5.64
1.29 / 5.23
0.166Hz rise 1s, stable 4s, fall
1s
Siren style tone
8
0,1,1,1,1
31
Sweep
800 – 1000
2.49 / 6.43
1.6 / 5.54
1.24 / 5.18
2Hz
8
1,1,1,1,1
32
Sweep
2400 - 2850
5.79 / 9.73
3.26 / 7.2
1.74 / 5.68
1Hz
10
Maximum consumption (mA)
Table 1 - VERSION 8C
DIMENSIONS
All DBS Variants
121mm
51mm
106mm
For Isolated variants add 0.19mA
to high,medium, low values
above.
We reserve the right to amend
the content of this document
without prior notice.
Sounder Output data, in
accordance with EN54-3, is
available on Document Ref:
D 1022.
0832
For CPD Data on all relevant
devices please request D974.
IMPORTANT NOTES:
ADDRESS SETTING
To set one of the 159 available addresses for the device use the two rotary switches located either side of the dip switch unit. The ‘tens’ digits go from 0 to 15 and the ‘units’ from 0 to 9.
Isolated
Non-Isolated
Example A (Address setting 108)
Example B (Address setting 98)
Isolated
Non-Isolated