F-38 PREPARATION BEFORE STARTING MASS PRODUCTION
<Soft-keys>
9-6
Setting Items Displayed at the Load Monitor Screen
This section describes the setting items displayed at the LOAD MONITOR SETTING screen.
<Display and Setting>
Display and set the information for each group.
Soft-Keys
Function
[MODE]
The operation mode changes in the order indicated below when this
soft-key is pressed.
The mode name of the selected mode is highlighted.
No mode names are highlighted when the mode is not selected.
[SETING]
The LOAD MONITOR SETTING screen is displayed when this soft-key
is pressed.
[EXIT]
The screen returns to the PCMDI MENU screen when this soft-key is
pressed.
Item
Description
GROUP
The group number of the data presently displayed is displayed.
The group number is changed by pressing the page selection keys.
The group data is displayed for up to 24 groups.
STD (%)
The maximum load detected during the cutting of the specified group is
displayed.
The maximum value is recorded and set by the teaching
operation and it is not possible to change the set value.
WRN (%)
Set the threshold level value of warning.
Setting is possible in the range from 0 to 999%.
ALM (%)
Set the threshold level value of alarm.
Setting is possible in the range from 0 to 999%.
Teaching
mode
Monitoring
mode
No mode
NOTE