background image

LAST UPDATED: 11/27/2018

Turret Indexer Assembly - SL-10/30 ST-10/15 - Troubleshooting Guide

Turret Indexer Assembly

Symptom Table

1. Air Cylinder
Assembly

19. Coolant Elbow

2. Motor

20. Coolant Transfer
Assembly

3. Worm Housing

21. TC Turret Cams (2)

4. Coupling Assembly 22. 15/16 Steel Balls (3)
5. Coolant Line
Assembly

23. Turret Retainer

6. Worm Shaft

24. TC Turret Shaft

7. TC Transfer Shaft

25. TC Cam Lever

8. Turret Home Switch 26. Die Spring Retainer
9. TC Switch Ring

27. Die Spring

10. Turret Switch
Bracket

28. Cam Cage

11. Bulkhead Fitting

29. Male Turret Coupling

12. Coolant Valve

30. Female Turret Coupling

13. Coolant Knob

31. Turret Mount Coupling

14. Bearing Nut N-13 32. TC Cluster Gear
15. Coolant Line

33. TC Turret Housing

16. TC Spur Gear
(keyed)

34. Turret Unclamp Sensor

17. Belleville Washers
(2)

35. Turret Clamp Sensor

18. TC Belleville
Spacer

Turret Indexer Assembly - SL-10/30 ST-10/15 - Troubleshooting Guide

Page 1 of 5 pages

Summary of Contents for ST-10/30

Page 1: ...aft 7 TC Transfer Shaft 25 TC Cam Lever 8 Turret Home Switch 26 Die Spring Retainer 9 TC Switch Ring 27 Die Spring 10 Turret Switch Bracket 28 Cam Cage 11 Bulkhead Fitting 29 Male Turret Coupling 12 Coolant Valve 30 Female Turret Coupling 13 Coolant Knob 31 Turret Mount Coupling 14 Bearing Nut N 13 32 TC Cluster Gear 15 Coolant Line 33 TC Turret Housing 16 TC Spur Gear keyed 34 Turret Unclamp Sens...

Page 2: ...r Turret is out of alignment Check Turret Motor coupling adjustment Mechanical binding of turret Check turret for possible turret o ring damage or chip intrusion Alarm 114 TURRET failure to reach the Clamp switch Alarm 2023 Turret failure to leave unclamp switch The turret clamp sensor is faulty or out of adjustment Check the turret clamp sensor Unusual noise as the turret rotates Tool Turret Die ...

Page 3: ...UIDE Pre CALM System Power off lock and tag out the machine Remove the left rear machine enclosure panel Locate the clamp unclamp solenoid and power connection behind the Tool Turret assembly Remove lock out tags power up and zero return the machine Use needle tipped probes and take care not to touch probes tips together when checking voltage Set the meter to AC voltage In MDI command an M43 and p...

Page 4: ...agnet did not activate the sensors inspect the cables If the cables are not damaged then the sensor will need to be replaced If the sensors were activated then they may need to be adjusted Verify the motor coupler alignment before adjusting sensors Refer to ST 10 10Y SL 10 30 TL 15 25 HL 1 6 TURRET LOCK AND UNLOCKED SENSORS ADJUSTMENT procedure Corrective Action With the turret clamped rotate the ...

Page 5: ... and inspect for possible damage Alignment If the turret is knocked out of alignment you may have to re align the turret motor coupler Refer to SL 10 20 30 ST 10 10Y MOTOR COUPLING ALIGNMENT procedure If the turret is knocked out of alingment a full geometry inspection should be done Make corrections as needed Servo Motor Corrective Action The servo motor has an electrical fault Possible failed mo...