background image

Air Cylinder

Clamp/Unclamp Sensors

Turret Die Springs

Corrective Action:

With the turret clamped test the air cylinder for
faulty piston seal.

Remove the upper hose (unclamp) on the cylinder.

If air is escaping from the upper hose (unclamp)
connection on the cylinder the cylinder piston seal
is bad and piston should be replaced.

Corrective Action:

Check the turret unclamp and clamp sensors.

Use a magnet and pass it over the sensors. Watch
the diagnostics screen to make sure they activate
with the magnet.

If the magnet did not activate the sensors inspect
the cables. If the cables are not damaged then the
sensor will need to be replaced.

If the sensors were activated then they may need to
be adjusted. Verify the motor coupler alignment
before adjusting sensors. Refer to

ST-10/10Y,

SL-10-30, TL-15/25, HL-1-6 - TURRET LOCK AND
UNLOCKED SENSORS - ADJUSTMENT

procedure.

Corrective Action:

With the turret clamped, rotate the turret back and
forth by hand. If there is movement in the turret the
die springs are broken and need to be replaced.

Refer to

HL/SL/ST-10 - TURRET -

REPLACEMENT

from the manual. Once the turret is

removed the springs can be replaced.

Turret Indexer Assembly - SL-10/30 ST-10/15 - Troubleshooting Guide

Page 4 of 5 pages

Summary of Contents for ST-10/30

Page 1: ...aft 7 TC Transfer Shaft 25 TC Cam Lever 8 Turret Home Switch 26 Die Spring Retainer 9 TC Switch Ring 27 Die Spring 10 Turret Switch Bracket 28 Cam Cage 11 Bulkhead Fitting 29 Male Turret Coupling 12 Coolant Valve 30 Female Turret Coupling 13 Coolant Knob 31 Turret Mount Coupling 14 Bearing Nut N 13 32 TC Cluster Gear 15 Coolant Line 33 TC Turret Housing 16 TC Spur Gear keyed 34 Turret Unclamp Sens...

Page 2: ...r Turret is out of alignment Check Turret Motor coupling adjustment Mechanical binding of turret Check turret for possible turret o ring damage or chip intrusion Alarm 114 TURRET failure to reach the Clamp switch Alarm 2023 Turret failure to leave unclamp switch The turret clamp sensor is faulty or out of adjustment Check the turret clamp sensor Unusual noise as the turret rotates Tool Turret Die ...

Page 3: ...UIDE Pre CALM System Power off lock and tag out the machine Remove the left rear machine enclosure panel Locate the clamp unclamp solenoid and power connection behind the Tool Turret assembly Remove lock out tags power up and zero return the machine Use needle tipped probes and take care not to touch probes tips together when checking voltage Set the meter to AC voltage In MDI command an M43 and p...

Page 4: ...agnet did not activate the sensors inspect the cables If the cables are not damaged then the sensor will need to be replaced If the sensors were activated then they may need to be adjusted Verify the motor coupler alignment before adjusting sensors Refer to ST 10 10Y SL 10 30 TL 15 25 HL 1 6 TURRET LOCK AND UNLOCKED SENSORS ADJUSTMENT procedure Corrective Action With the turret clamped rotate the ...

Page 5: ... and inspect for possible damage Alignment If the turret is knocked out of alignment you may have to re align the turret motor coupler Refer to SL 10 20 30 ST 10 10Y MOTOR COUPLING ALIGNMENT procedure If the turret is knocked out of alingment a full geometry inspection should be done Make corrections as needed Servo Motor Corrective Action The servo motor has an electrical fault Possible failed mo...

Reviews: