A-46 OPERATION PANELS
The STATUS indicator
[M02/M30]
is lit and the machine stops in the following
cases:
1.
When an M02 command (program end) is read.
2.
When an M30 command (program end and rewind) is read.
In a program, specify the M02/M30 command in an independent block.
The STATUS indicator
[CHCL]
is lit when the chuck is in the clamp state.
In this state, spindle rotation is possible in both automatic and manual operations.
The STATUS indicator
[CHCL]
is not lit when the chuck is in the unclamp state.
The spindle cannot rotate unless this indicator is lit.
If automatic operation cannot be started, check whether or not this
indicator is lit.
The status indicator
[HEADSTOCK 2 CHUCK CLAMP]
on the option panel is lit
when chuck 2 is in the clamp state. (S type)
Automatic operation is impossible unless chuck 2 is in the clamp state.
The status indicator
[HEADSTOCK 2 CHUCK CLAMP]
is not lit when chuck 2 is
in the unclamp state.
The spindle cannot rotate unless this indicator is lit.
If automatic operation cannot be started, check whether or not this indicator is lit.
After turning on of the power supply, the lamp lights when the conditions
necessary for machine operation are arranged.
Machine operation is impossible unless this indicator is lit.
The fact that this indicator is lit means that the electrical system is
operating correctly.
Start machine operation only after making sure that the operation can be
started safely by checking the machine condition, cutting tool(s),
workpiece, working environment and program.
The STATUS indicator
[TRCL]
shows whether the turret head is clamped
correctly or not.
Automatic operation is impossible unless this indicator is lit.
The STATUS indicator
[TRCL]
is lit when the turret has been indexed and
clamped correctly.
The STATUS indicator
[TRCL]
blinks if the turret has not been indexed correctly.
The STATUS indicator
[X/Z]
is lit when the X-/Z-axis has been returned to the
zero point.
These indicators are used to check if the axes have returned to the zero point.
The status indicator
[B-AXIS ZERO POINT]
on the option panel is lit when the B-
axis has been returned to the zero point. (S type)
This indicator is used to check if the axis has returned to the zero point.
Status indicator
Contents of Indication
M02/M30
NOTE
CHCL
NOTE
HEADSTOCK 2 CHUCK CLAMP
MRDY
NOTE
TRCL
X
Z
B-AXIS ZERO POINT