OPERATION PANELS A-43
5-6-15
Spindle OFF Mode Function
The spindle OFF mode function is made valid or invalid on
the OPERATION PANEL screen, which is displayed by
pressing the function selection key
(SETTING).
The valid and invalid status of the spindle OFF
mode function changes simultaneously when the
status is changed for either of turret 1 and turret 2.
(S type)
<Spindle OFF mode function>
The spindle OFF mode function is used to determine whether or not the following M code
functions are actually executed when checking a program without mounting a workpiece in the
machine.
M Code
Function
M03
Spindle start (normal)
M04
Spindle start (reverse)
M08
Coolant supply
M13
Rotary tool spindle start (normal) (MC type)
M14
Rotary tool spindle start (reverse) (MC type)
M19
Spindle orientation (option)
M34
Phase synchronous operation ON (S type)
M35
Speed synchronous operation ON (S type)
M41
Spindle gear 1st range (transmission specification)
M42
Spindle gear 2nd range (transmission specification)
M43
Spindle gear 3rd range (transmission specification)
M44
Spindle gear 4th range (transmission specification)
M64
Robot service call (robot specification)
M70
Bar feeder operation (bar feeder specification)
M80
Cut-off check (S type)
M203
Spindle 2 start (normal) (S type)
M204
Spindle 2 start (reverse) (S type)
M219
Spindle 2 orientation (option) (S type)
SETTING
NOTE